background image

1. POWER
Press this key to turn “on” or “off”, and the relating 

indicating light may follow the instruction to 

illuminate or extinguish. (While the unit is defrost-

ing, the indicating light may lights on and off in 

turn shortly.)
2. FAN SPEED
Press the key to choose high speed (HI) or low 

speed (LOW), and the relating indicating light may 

follow the instruction to illuminate or extinguish.
3. TIMER
a. Press the key to set time you need. (1 to 24 

hours)
b. When setting timer in stand-by mode, the unit 

will be turned on automatically; when setting timer 

in operating mode, the unit will be turned off 

automatically.
c. If pressing the power key to turn off the unit 

before time finishes counting down, the setting 

timer will be canceled.
d. While the timer is in used, the indicating light 

illuminates; if not, then the indicating light 

extinguishes.
e. After set the timer 5 seconds, the display may 

switch back to show the ambient humidity.(Press 

once again can show the turning-off time.)
4. HUMIDITY SETTING
Press the key to set the relative humidity you need. 

(From continuous dehumidification [CO] to relative 

humidity 50%, 60%, 70%, 80%, comfort mode [AU], 

and back to continuous dehumidification [CO]. The 

first time you electrify the unit, the unit is set to be 

continuous dehumidification [CO].

When ambient humidity is lower than setting humidi-

ty by 3%, compressor will stop automatically, and 

return working until the ambient humidity is higher 

than setting humidity by 3%.
COMFORT MODE [AU]
a. When ambient temperature is lower than 5°C, 

compressor will stop working.
b. When ambient temperature is higher than 5°C and 

lower than 20°C, the product will set the humidity to 

60% automatically.
c. When ambient temperature is higher than 20°C and 

lower than 27°C, the product will set the humidity to 

55% automatically.
d. When ambient temperature is higher than 27°C, the 

product will set the humidity to 50% automatically.
WATER FULL
When the water tank is full, the indicating light will 

illuminate and the unit will stop working until empty 

the water tank.
DEFROST
When the unit is defrosting, the indicating light will 

illuminate and the compressor will stop working but 

the motor will keep operating.
WARNING
1. When operating the dehumidifier, please do not set 

the humidity higher than ambient humidity.
2. When indicating light illuminates, please pour the 

water out of the tank and put it back. Then the 

product will resume working.
3. When the product shut down, please wait at least 3 

minutes before restarting the unit to prevent damag-

ing the compressor.

CONTROL PANEL DESCRIPTION 

OPERATING INSTRUCTION

2

EN

Ref. 636134

DEHUMIDIFIER

DESHUMIFICADOR

Содержание 636134

Страница 1: ...ER USER S MANUAL MANUAL DEL USUARIO Please read this manual before use Porfavor leer el manual antes de usar Distribuido por HORTICULTURA T CNICA S L U CIF B97303937 C AIG ADERS N 4 46680 ALGEMESI VAL...

Страница 2: ...m power supply before moving or cleaning the product and also when the product is not in used 14 Please operate the product with specified electricity voltage 15 Please use this product only for house...

Страница 3: ...nit the unit is set to be continuous dehumidification CO When ambient humidity is lower than setting humidi ty by 3 compressor will stop automatically and return working until the ambient humidity is...

Страница 4: ...to let water flow out FILTER REMOVAL 1 Take out the water tank before remove the filter 2 Pulling out the filter with handles of filter 3 Wash the filter with cool water cooler than 40 C every two wee...

Страница 5: ...ately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continue during the period that the work is carried out The ventilation should safely disperse...

Страница 6: ...ffects of aging or continual vibration from sources such as compressors or fans 5 DETECTION OF FLAMMABLE REFRIGERANTS Under no circumstances shall potential sources of ignition be used in the searchin...

Страница 7: ...re attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available and being used correctl...

Страница 8: ...f cm2 Dimension W x D x H mm 360Wx246Dx506H Applicable temperature 5 C 35 C Water Tank Capacity 3 2 L SPECIFICATIONS Power Supply Power Input Moisture Removal Refrigerant Model REF 636134 30 C RH80 22...

Страница 9: ...a causar da os a los usuarios 13 Desconecte el electrodom stico de la fuente de alimentaci n antes de moverlo o limpiarlo y tambi n cuando el producto no se utilice 14 Utilice el producto con la tensi...

Страница 10: ...a humedad relativa 50 60 70 u 80 modo de confort AU y otra vez a deshumidificaci n contin uada CO La primera vez que la encienda la unidad est configurada en el modo de deshumidi ficaci n continuada...

Страница 11: ...e PVC El tubo de PVC no se incluye con el producto USO DEL DEP SITO DE AGUA Cuando el producto est deshumidificando el agua que se condense puede drenarse en el dep sito de agua Cuando el dep sito de...

Страница 12: ...dante Antes de comen zar el trabajo la zona adyacente al equipo se debe inspeccionar para descartar la presencia de peligros inflamables o riesgos de ignici n Deber n ponerse carteles de Prohibido fum...

Страница 13: ...uso de silicona sellante puede mermar la eficacia de algunos equipos de detecci n de fugas No es preciso aislar los componentes con seguridad intr nseca antes de trabajar en ellos 3 REPARACI N DE LOS...

Страница 14: ...la bomba de vac o no est cerca de ninguna fuente de ignici n y de que la zona est bien ventilada 8 PROCEDIMIENTOS DE CARGA Adem s de los procedimientos de carga conven cionales deben cumplirse los req...

Страница 15: ...rante es decir deben ser cilindros especiales para la recuperaci n de refrigerante Los cilindros deben contar con una v lvula de alivio de presi n y con v lvulas de cierre en buen estado Los cilindros...

Страница 16: ...UNIDADES 1 Transporte de equipo que contenga refrigerantes inflamables Cumplimiento de las normas de transporte 2 Marcado del equipo mediante se ales Cumplimiento de la normativa local 3 Eliminaci n d...

Отзывы: