background image

1. Do not use means to accelerate the defrosting 

process or to clean, other than those recommended by 

the manufacturer.
2. The appliance shall be stored in a room without 

continuously operating ignition sources (for example: 

open flames, an operating gas appliance or an operating 

electric heater.)
3. Do not pierce or burn.
4. Be aware that refrigerants may not contain an odour.
5. Appliance shall be installed, operated and stored in a 

room with a floor area larger than 12m

2

6. Servicing shall be performed only as recommended by 

the manufacturer.
7. The appliance shall be stored in a well- ventilated area 

where the room size corresponds to the room area as 

specified for operation.
8. All working procedure that affects safety means shall 

only be carried by competent persons.
9. Please read the manual carefully before the first time 

using this product, and storage the unit in safe place to 

avoid electricity leakage, flaming or person injure.
10.Do not put this product in the water or any other 

liquids.
11.If the supply cord is damaged, it must be replaced by 

the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard..
12.Please ask professional service agent to repair the 

product. Improper repair might cause damage to users.
13.Disconnect the appliance from power supply before 

moving or cleaning the product, and also when the product 

is not in used.
14.Please operate the product with specified electricity 

voltage.
15.Please use this product only for household appliance 

and follow the designed purpose.
16.Do not put any stuff on the product.
17.In order to avoid water leakage, please clean the water 

tank before moving the product.
18.Do not incline the product, or leaking water may 

damage the product.
19.This appliance can be used by children aged from 8 

years and above and persons with reduced physical, 

sensory or mental capabilities or lack of experience and 

knowledge if they have been given supervision or instruc-

tion concerning use of the appliance in a safe way and 

understand the hazards involved. Children shall not play 

with the appliance. Cleaning and user maintenance shall 

not be made by children without supervision.
20.Please keep the product from the wall or other barriers 

in a minimum distance of 50 cm.
21.The appliance shall be installed in accordance with 

national wiring regulations.
22.The applicable operating temperature range for this 

unit is 5-35°C.
23.Do not operate your dehumidifier in a wet room such as 

a bathroom or laundry room.
24. Spaces where refrigerant pipes shall be compliance 

with national gas regulations.

SAFETY INFORMATION

1. CONTROL PANEL
2. AIR OUTLET
3. HANDEL
4. FRONT HOUSING
5. AIR INLET /
    BACK HOUSING
6. DRAIN HOLE
7. WATER TANK

1

OPERATING 

INSTRUCTION

EN

Ref. 636134

DEHUMIDIFIER

DESHUMIFICADOR

Содержание 636134

Страница 1: ...ER USER S MANUAL MANUAL DEL USUARIO Please read this manual before use Porfavor leer el manual antes de usar Distribuido por HORTICULTURA T CNICA S L U CIF B97303937 C AIG ADERS N 4 46680 ALGEMESI VAL...

Страница 2: ...m power supply before moving or cleaning the product and also when the product is not in used 14 Please operate the product with specified electricity voltage 15 Please use this product only for house...

Страница 3: ...nit the unit is set to be continuous dehumidification CO When ambient humidity is lower than setting humidi ty by 3 compressor will stop automatically and return working until the ambient humidity is...

Страница 4: ...to let water flow out FILTER REMOVAL 1 Take out the water tank before remove the filter 2 Pulling out the filter with handles of filter 3 Wash the filter with cool water cooler than 40 C every two wee...

Страница 5: ...ately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continue during the period that the work is carried out The ventilation should safely disperse...

Страница 6: ...ffects of aging or continual vibration from sources such as compressors or fans 5 DETECTION OF FLAMMABLE REFRIGERANTS Under no circumstances shall potential sources of ignition be used in the searchin...

Страница 7: ...re attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is available and being used correctl...

Страница 8: ...f cm2 Dimension W x D x H mm 360Wx246Dx506H Applicable temperature 5 C 35 C Water Tank Capacity 3 2 L SPECIFICATIONS Power Supply Power Input Moisture Removal Refrigerant Model REF 636134 30 C RH80 22...

Страница 9: ...a causar da os a los usuarios 13 Desconecte el electrodom stico de la fuente de alimentaci n antes de moverlo o limpiarlo y tambi n cuando el producto no se utilice 14 Utilice el producto con la tensi...

Страница 10: ...a humedad relativa 50 60 70 u 80 modo de confort AU y otra vez a deshumidificaci n contin uada CO La primera vez que la encienda la unidad est configurada en el modo de deshumidi ficaci n continuada...

Страница 11: ...e PVC El tubo de PVC no se incluye con el producto USO DEL DEP SITO DE AGUA Cuando el producto est deshumidificando el agua que se condense puede drenarse en el dep sito de agua Cuando el dep sito de...

Страница 12: ...dante Antes de comen zar el trabajo la zona adyacente al equipo se debe inspeccionar para descartar la presencia de peligros inflamables o riesgos de ignici n Deber n ponerse carteles de Prohibido fum...

Страница 13: ...uso de silicona sellante puede mermar la eficacia de algunos equipos de detecci n de fugas No es preciso aislar los componentes con seguridad intr nseca antes de trabajar en ellos 3 REPARACI N DE LOS...

Страница 14: ...la bomba de vac o no est cerca de ninguna fuente de ignici n y de que la zona est bien ventilada 8 PROCEDIMIENTOS DE CARGA Adem s de los procedimientos de carga conven cionales deben cumplirse los req...

Страница 15: ...rante es decir deben ser cilindros especiales para la recuperaci n de refrigerante Los cilindros deben contar con una v lvula de alivio de presi n y con v lvulas de cierre en buen estado Los cilindros...

Страница 16: ...UNIDADES 1 Transporte de equipo que contenga refrigerantes inflamables Cumplimiento de las normas de transporte 2 Marcado del equipo mediante se ales Cumplimiento de la normativa local 3 Eliminaci n d...

Отзывы: