2.1.4 Used presentations & symbols
The graphical presentation depends on the current situation.
2.1.4.1 Cell
Fig. 16
Cell status
2.1.4.2 Fan
When DC fans are used, the speed of the fans is shown in percentage of full speed. Full speed is 100%.
Fig. 17
Fan status
2.1.4.3 Evaporator
Fig. 18
Evaporator status
(De)activate
sensors & zones
Use right mouse button to
de-activate sensors and zones
individually. De-activated items
are greyed out.
activated
de-activated
Gassing phase active
Humidifying phase active
Ventilation phase active
Fan off
Fan on
Fan on reverse
Evaporator - cooling
Evaporator - off
Evaporator - heating