![vc999 RS420 Скачать руководство пользователя страница 29](http://html2.mh-extra.com/html/vc999/rs420/rs420_maintenance-manual_3674555029.webp)
INSPECTION SCHEDULE
Vacuum pump
•
Change initial factory oil after 500 hours of service or 5 weeks.
o
Recommended oil is
ISO VG-100
o
Or SAE equivalent of 33W non-detergent.
o
90-weight oil is not recommended.
•
Change oil every 500 hours of service.
•
If severe operating conditions exist the time interval must be shortened.
o
Pump capacity is approximately 6 liters.
o
Pump manufacturer recommends the following oil brands:
BP Energol RC 100
EssoTeresso
100
Mobil DTE Oil extra heavy
Shell Corena Oil P 100
Or equivalent oils from other manufacturers.
•
Regularly clean the inlet filter by washing and/or blowing it out with compressed air.
o
Replace the inlet filter if it is damaged or completely contaminated.
•
Changing the exhaust filter elements is recommended every 2000 operating hours.
o
It is not possible to clean these elements.
Содержание RS420
Страница 1: ...MAINTENANCE MANUAL FAX 816 472 1999 PHONE 816 472 8999 TOLL FREE 1 800 235 2829 E MAIL vc999 vc999 com...
Страница 6: ...SECTION 1 SAFETY...
Страница 11: ...SECTION 2 TRANSPORTATION...
Страница 13: ...SECTION 3 INSTALLATION...
Страница 19: ...SECTION 4 INTERFACE TOUCH SCREEN...
Страница 26: ...SECTION 5 MAINTENANCE INSPECTION SCHEDULE...
Страница 39: ...SECTION 6 TROUBLESHOOTING GUIDE...
Страница 55: ...SECTION 7 PNEUMATIC DIAGRAMS...
Страница 73: ...SECTION 8 ELECTRICAL DIAGRAMS...
Страница 91: ...SECTION 9 PARTS LIST ASSEMBLY DRAWINGS...
Страница 148: ...Parts 8 12 Vacuum Valve O Ring Replacement Kit...
Страница 149: ...SECTION 10 DIE ASSEMBLY DRAWINGS...
Страница 156: ...NOTES...
Страница 157: ...NOTES...