Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1.5”), RS485
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
289111EB
2013-02-05
81/96
Description
Required tool
14. Pay attention that grease is distributed
constantly over the whole circumference.
15. Place the new o-ring at o-ring groove at
one side
16. Move the o-ring in the o-ring groove on the
other side
Rep
la
c
e
o
-ri
n
g
s
f
ro
m
p
la
te
17. Push in the o-ring around the plate into o-
ring groove equally
18. Plate with equal mounted o-ring