Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1.5”), RS485
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
289111EB
2013-02-05
63/96
Setup function
Command
Acknowledgement
(within 10ms after reception of
command)
Description
DIGITAL INPUT
(LOGIGC I/O)
Set
[s:2601][abcdef][CR]
[s:2601][CR]
Get
[i:2601][CR]
[i:2601][abcdef][CR]
data length 6 characters
a
0
= close valve
1
= open valve
b
0
= non inverted
1
= inverted
c
0
= enabled
1
= disabled
def
000
(reserved)
This function does the „DIGITAL INPUT‟ configuration.
DIGITAL OUTPUT
(LOGIGC I/O)
Set
[s:2611][abcdef][CR]
[s:2611][CR]
Get
[i:2611][CR]
[i:2611][abcdef][CR]
data length 6 characters
a
0
= close
1
= open
b
0
= non inverted
1
= inverted
c
0
= enabled
1
= disabled
def
000
(reserved)
This
function does the „DIGITAL OUTPUT‟ configuration.