Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1.5”), RS485
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
289111EB
2013-02-05
68/96
VALVE SPEED
Set
[V:][00xxxx][CR][LF]
[V:][CR][LF]
Get
[i:68][CR][LF]
[i:68][0000xxxx][CR][LF]
data length 6 characters starting with double zero for writing
8 characters starting with quadruple zero for reading
xxxx
valve speed,
1
...
1000
(1 = min. speed, 1000 = max. speed)
This command allows changing the actuating speed of the valve plate. Speed selection is
effective for pressure control and position control. Open valve and close valve are always
done with max. speed.
Note:
Refer to «Valve speed adjustment» for details.
RESET
Set
[c:82][xx][CR][LF]
[c:82][CR][LF]
data length 2 characters
xx
00
= reset service request bit from WARNINGS
01
= reset FATAL ERROR (restart control unit)
This function resets warnings and errors.