Important:  

Damages caused by the disregard of this user manual are not subject to 

warranty. The dealer will not accept liability for any resulting defects or 

problems. Make sure the electrical connection is carried out by qualified 

personnel. All electrical and mechanical connections have to be carried out 

according to the European safety standards. 

2.  Before usage 

2.1. Carton  

1 x Flatbeam Duo 

1 x Power Cable with Plug 

1 x DMX Input Cable 

1 x User Manual 

2.2. Unpacking 

Every Flatbeam Duo has been thoroughly tested and has been transported in perfect operating 

condition. Carefully check the carton for damages that may have occurred during the transport. If 

the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all 

accessories necessary to operate the unit has arrived intact.  

2.3. AC Power 

This fixture has an auto-switching power supply that can accommodate a wide range of input 

voltages. The only thing necessary to do before powering on the unit is to make sure the line 

voltage you are applying is within the range of accepted voltage. This fixture will accommodate 

between 100V and 240V AC 50~60Hz. All fixtures must be powered directly off a switched circuit 

and cannot be run off a rheostat. 

 

3.  Introduction 

3.1. Features 

3, 4, 5, 6 or 11 Channel DMX 512 Control Operating Modes. 

3 Channel = RGB control 

3 Channel = HSV control (hue, saturation and value) 

4 Channel = RGB, Dimmer 

4 Channel = RGBW Control 

5 Channel = RGBW Dimmer 

6 Channel = RGBW Dimmer Strobe 

11 Channel = RGBW, ID, dimmer, strobe, autospeed, auto, custom programs, aso. 

Light source 48 x 8W 4in1 High Power Leds 

Lens: 51° Standard Lens 

Material: aluminum body 

Protection Rating: IP67 

Power Consumption: 400W 

Содержание FLATBEAM DUO 48x8W RGBW

Страница 1: ...User manual FLATBEAM DUO 48x8W RGBW...

Страница 2: ...3 2 DMX data cable 9 4 3 3 Cable Connectors 10 4 3 4 3 Pin to 5 Pin conversion chart 10 4 3 5 Setting up a DMX serial data link 10 4 3 6 Master Slave fixture linking 11 5 Operating Instructions 11 5...

Страница 3: ...3 21 5 6 8 Setting 15 5 6 9 RGbW White adjust 16 5 6 10 CAL1 16 5 6 11 CAL2 16 5 6 12 Key Lock 16 5 7 DMX 512 channel values 17 6 DMX Primer 20...

Страница 4: ...a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoi...

Страница 5: ...d be sure all accessories necessary to operate the unit has arrived intact 2 3 AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thi...

Страница 6: ...erent personalities can be accessed from the control panel Please see section about Control Panel Functions for a description and how to accomplish that STAG Channel Description 1 Dimmer 2 Red set the...

Страница 7: ...hannel Description 1 Dimmer 2 Red 3 Green 4 Blue 5 White Ar 2s Channel Description 1 Dimmer 2 Red 3 Green 4 Blue 5 White 6 Strobe HSV Channel Description 1 Hue 2 Saturation 3 Value Brightness 3 3 Prod...

Страница 8: ...re Connection Pin Brown AC Live 1 Blue AC neutral 2 Green Yellow AC Ground 3 4 2 Mounting This fixture may be mounted in any safe position The fixture includes a mounting yoke to which a rigging clamp...

Страница 9: ...nded serial data link distance 500m 1640ft maximum recommended number of fixtures on a serial data link 32 Fixtures 4 3 1 Data Cabeling To link fixtures together you must obtain data cables You can pu...

Страница 10: ...her 4 3 4 3 Pin to 5 Pin conversion chart Note If you use a controller with 5 Pin DMX output connector you will need to use a 5pin to 3pin adapter The chart below details a proper cable conversion 4 3...

Страница 11: ...to 3696 fixtures The flatbeam Duo ID address system is accessed using DMX channel 11 STAG consideration must be placed when programming live performances or cues that need to trigger on demand on a ti...

Страница 12: ...DRESS to 01 66 3 5 5 Setting the DMX address Each fixture requires a start address from 001 512 A fixture requiring one more channels for control begins to read the data on the channel indicated by st...

Страница 13: ...ards through the menu list and Increases the numeric value when in a function DOWN Navigates downwards through the menu list and decreases the numeric value when in a function ENTER Enables the curren...

Страница 14: ...Aut 10 are fully pre programmed and will not be altered by changes in EDIT mode Programs Pro 01 to Pro 10 are fully pre programmed and can be edited in EDIT mode 5 6 3 Run Enter the RUN mode to set th...

Страница 15: ...UPLD to upload the custom programs from the current MASTER unit to SLAVE units The SLAVE units must be set in mode RUN to Slave In order to activate the upload function the password must be entered Th...

Страница 16: ...e nin linear dimmer DIM1 is the faster while DIM4 is the slowest The DIM setting here does not react on the STAG mode 5 6 10 CAL1 Enter the CAL1 to select white color of different color temperature Th...

Страница 17: ...17 21 5 7 DMX 512 channel values...

Страница 18: ...18 21 Important Master Dimmer Channel 1 controls the intensity of the currently projected color When the slider is at the highest position 255 then the intensity of the output is at the maximum...

Страница 19: ...fixtures Each independent DMX address can have up to 66 ID addresses fixtures ID address 0 allows control of all fixtures simultaneously Auto custom Program Chanel 8 selects prest Auto Custom Programs...

Страница 20: ...You can however control multiple fixtures of the same type by using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be...

Страница 21: ...21 21 Importer B K Braun GmbH Industriestra e 2 D 76307 Karlsbad www bkbraun com info bkbraun com...

Отзывы: