4.  Setup 

4.1. Power Supply 

Before plugging in your unit, make sure that the voltage in your area is matching the required voltage 

of your Flatbeam. This unit has an auto switching PSU which offers  a wide range of input voltages. 

The only thing you have to do before powering up, is to check if the line voltage you are connected to 

is matching the range of accepted voltages. This fixture works between 100V and 240V 50/60 Hz. All 

fixtures must be powered off a switched circuit and cannot be run on a rheostat (variable resistor) or 

dimmer circuit. It is even not possible to do so if the dimmer is a switch working with 0% and 100% 

only. This item is designed for power linking from one flatbeam to the other. Each fixture ships with 

IP65 proprietary power input cables. Each fixture ships with a power adapter to male Edison 

connector. 

 

All fixtures must be connected to circuits with a suitable Earth Ground. Depending on the application 

the lighting fixture may require a different connector. Please refer to the below wire color code for 

installing a new connector: 

Wire 

Connection 

Pin 

Brown 

AC Live 

Blue 

AC neutral 

Green/Yellow 

AC Ground 

 

4.2. Mounting 

This fixture may be mounted in any safe position.  

 

The fixture includes a mounting yoke to which a rigging clamp can be attached. You must supply your 

own clamp and make sure the clamp is capable of supporting the weight of this fixture. It is 

recommended to use at least 2 mounting points per fixture.  

Note: There are 2 types of applications for this fixture: floor stand for up lighting and overhead use for 

down lighting. If you are using this fixture for down lighting from up above you must use at least 1 

safety cable/chain for each fixture in addition to the mounting brackets. 

 

1.  If hanging the fixture for over head use, then please follow below steps. 

2.  Block access below the work area and use suitable and stable platform when installing or 

servicing the fixture. 

3.  Safety cables must always be used, secured through safety cable attachment. The safety 

cable must be capable of holding 10 times the weight of the fixture. 

4.  Verify the structure can hold 10 times the weight of all to be installed fixtures. After prolonged 

periods of operation, the fixture chassis may reach high temperatures. This fixture must be 

mounted in a ventilated location, as it is convection cooled. 

 

 

Содержание FLATBEAM DUO 48x8W RGBW

Страница 1: ...User manual FLATBEAM DUO 48x8W RGBW...

Страница 2: ...3 2 DMX data cable 9 4 3 3 Cable Connectors 10 4 3 4 3 Pin to 5 Pin conversion chart 10 4 3 5 Setting up a DMX serial data link 10 4 3 6 Master Slave fixture linking 11 5 Operating Instructions 11 5...

Страница 3: ...3 21 5 6 8 Setting 15 5 6 9 RGbW White adjust 16 5 6 10 CAL1 16 5 6 11 CAL2 16 5 6 12 Key Lock 16 5 7 DMX 512 channel values 17 6 DMX Primer 20...

Страница 4: ...a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoi...

Страница 5: ...d be sure all accessories necessary to operate the unit has arrived intact 2 3 AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The only thi...

Страница 6: ...erent personalities can be accessed from the control panel Please see section about Control Panel Functions for a description and how to accomplish that STAG Channel Description 1 Dimmer 2 Red set the...

Страница 7: ...hannel Description 1 Dimmer 2 Red 3 Green 4 Blue 5 White Ar 2s Channel Description 1 Dimmer 2 Red 3 Green 4 Blue 5 White 6 Strobe HSV Channel Description 1 Hue 2 Saturation 3 Value Brightness 3 3 Prod...

Страница 8: ...re Connection Pin Brown AC Live 1 Blue AC neutral 2 Green Yellow AC Ground 3 4 2 Mounting This fixture may be mounted in any safe position The fixture includes a mounting yoke to which a rigging clamp...

Страница 9: ...nded serial data link distance 500m 1640ft maximum recommended number of fixtures on a serial data link 32 Fixtures 4 3 1 Data Cabeling To link fixtures together you must obtain data cables You can pu...

Страница 10: ...her 4 3 4 3 Pin to 5 Pin conversion chart Note If you use a controller with 5 Pin DMX output connector you will need to use a 5pin to 3pin adapter The chart below details a proper cable conversion 4 3...

Страница 11: ...to 3696 fixtures The flatbeam Duo ID address system is accessed using DMX channel 11 STAG consideration must be placed when programming live performances or cues that need to trigger on demand on a ti...

Страница 12: ...DRESS to 01 66 3 5 5 Setting the DMX address Each fixture requires a start address from 001 512 A fixture requiring one more channels for control begins to read the data on the channel indicated by st...

Страница 13: ...ards through the menu list and Increases the numeric value when in a function DOWN Navigates downwards through the menu list and decreases the numeric value when in a function ENTER Enables the curren...

Страница 14: ...Aut 10 are fully pre programmed and will not be altered by changes in EDIT mode Programs Pro 01 to Pro 10 are fully pre programmed and can be edited in EDIT mode 5 6 3 Run Enter the RUN mode to set th...

Страница 15: ...UPLD to upload the custom programs from the current MASTER unit to SLAVE units The SLAVE units must be set in mode RUN to Slave In order to activate the upload function the password must be entered Th...

Страница 16: ...e nin linear dimmer DIM1 is the faster while DIM4 is the slowest The DIM setting here does not react on the STAG mode 5 6 10 CAL1 Enter the CAL1 to select white color of different color temperature Th...

Страница 17: ...17 21 5 7 DMX 512 channel values...

Страница 18: ...18 21 Important Master Dimmer Channel 1 controls the intensity of the currently projected color When the slider is at the highest position 255 then the intensity of the output is at the maximum...

Страница 19: ...fixtures Each independent DMX address can have up to 66 ID addresses fixtures ID address 0 allows control of all fixtures simultaneously Auto custom Program Chanel 8 selects prest Auto Custom Programs...

Страница 20: ...You can however control multiple fixtures of the same type by using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be...

Страница 21: ...21 21 Importer B K Braun GmbH Industriestra e 2 D 76307 Karlsbad www bkbraun com info bkbraun com...

Отзывы: