79
12.4.2
Network/portal connection
•
In Settings, select the
Network/portal connectionbutton.
As standard, the store assumes the settings of the customer network. To this end, the choice box beside
Activate DHCP is ticked.
Activate DHCP:
☒
IP address:
192.168.2.100
Net mask
255.255.255.0
DNS address:
192.168.2.1
Gateway:
192.168.2.1
Reset
Factory setting
OK
Activate DHCP:
With this option, the automatic receipt of the parameters of the customer network is activated.
IP address:
Is read out automatically.
Net mask
If DHCP is not activated, it must be entered manually.
DNS address:
Is read out automatically.
Gateway:
Is read out automatically.
i
If the IP address, the DNS address and the gateway are to be set up statically, knowledge of
the static address issue is required.
For this, it is e.g. necessary to read out the network configuration of the router.
The IP ranges 172.30.xxx.xxx to 172.31.xxx.xxx must not be used.
Should the connection not take place automatically, take the parameters from the manual of the network
router. With commercially available DSL routers, the DNS and gateway address are usually identical. In
company networks, they can differ. Additionally, the release of ports 4500, 21 and 37 is required for the
connection to the portal (does not apply to all users).
i
If the IP address, the DNS address and the gateway are to be set up statically, knowledge of
the static address issue is required.
For this, it is e.g. necessary to read out the network configuration of the router.
The address range 172.30.xxx.xxx and 172.31.xxx.xxx must not be issued as a static or dynamic
IP for the store.
12.4.3
Reboot
After parameters have been changed, a reboot is necessary.
•
To this end, switch the store “OFF” at the on/off switch and then “ON” again after a waiting time of
approximately 90 seconds.
•
Thereafter, checks are required on the
homepage and the System page.
12.4.4
Service settings
The following parameters can be set on this page:
Reboot time:
As standard, the reboot takes place between 3 and 4 am. An hour in the period between midnight
and midnight can be defined for the time of the reboot.
Reboot days:
The week day(s) for the reboot is/are defined using the choice box. At least one day must be
ticked.
Manual ventilator activation:
Selection between automatic (= 0), medium stage (= 1) and highest stage (= 2).
Reset air filter change
time:
The time until the next air filter change can be reset. To this end, tick the choice
box. A condition is that the air filter is actually replaced or cleaned.
Checking the current sensor:
Upon consultation with VARTA Service, the automatic current sensor check can
be disactivated.