Värmebaronen EK 15E

Alternative temperature with room unit

Upon activation, the centre point of the setpoint adjuster 
is moved by the set number of stages.

 

For example, the centre position of the handwheel is 20-6 = 
14°C if the alternative temperature parameter is set to -6.

Optional Room Unit

The control can be equipped with a room unit with a setpoint 
adjuster, handwheel and an alarm indicator, which has the 
same function as the red indicator on the front panel.
The room unit increases heating comfort with the lowest 
possible energy consumption. Additional information is 
included with the device.

 

Further information is provided with the room unit. 
The room unit requires that the UTK function is activated.
Room unit; "User level" rows 10 and 11 and "Service level" 
row 8.

Over temperature protection

The overtemperature protection supplements 
the overheating protection. The aim is to prevent the 
overheating protection from triggering as far as possible.
The temperature at which over-temperature protection 

is tripped can be set as a fixed value or in relation to the 

setpoint. See "Advanced Service level" rows 16 and 17.

Safety valve

To maintain the safety function, safety valves in the heating 
system must be operated regularly, about 4 times a year.

Venting - water pressure

Regularly check that the water pressure is correct. 
Air may be left in the system for a while after installation, 
for which reason it should be vented a few more times.

  The pressure in a heating system varies with the 

temperature. Do not add water unnecessarily!

Draining

If the heating system needs to be drained of water, 
the electric flow heater must first be switched off 
so that the immersion heater is not damaged.

Operation and maintenance

Overheating protection

The electric flow heater's overheating protection is triggered 
if the temperature exceeds approximately 100°C. Protection 
is reset when the "reset plug" on the front panel is removed. 

Reset can only be done when the temperature has fallen 

below 80°C.

  Always check the cause of a guard being 

triggered! If the protection is triggered 

repeatedly, the cause must be fixed!

Action in the event of a risk of freezing

When it is extremely cold, no part of the heating system 
must be switched off as there is a risk of bursting.
If you suspect that any part of the heating system is frozen, 
contact an installation engineer.

If the heating system is to be switched off for an extended 

period of time, the system should be drained or it can 
be filled with water mixed with glycol.

  The electric flow heater must not be operated 

if you suspect that any part of the heating 

system is frozen.

 

Call an installation engineer!

 

Frost protection - heating systems

If the heating system's water is mixed with glycol, 
it is important to check that the glycol contains a suitable 
quantity of corrosion-protection additive. When glycol 
breaks down, one of the by-products is carbonic acid, 
which increases the risk of corrosion.

Frost protection

The ECO function activates the frost protection automatically 
when the boiler temperature is below 10°C. See "User level" 
row 12.

Содержание EK 15 E

Страница 1: ...Installation and maintenance EK 15 E Electric flow heater 7 stage 14 7 kW 1212_EK15E_191017_en pwr 1 14 1 15 dsp 1 05 p typ 4...

Страница 2: ...sator setpoints UTK Alternative temperature Alternative temperature with room unit Optional Room Unit Over temperature protection Overheating protection Action in the event of a risk of freezing Frost...

Страница 3: ...onthat is important for optimum operation Tells you what you should or should not do to avoid personal injury Tells you what you should or should not do to prevent a component the electric flow heater...

Страница 4: ...the value is changed the indicator flashes The new value is only applied after confirming by pressing The old value is removed if the row is left with or User level Reading and modification of the mos...

Страница 5: ...rent alarm codes according to a rolling schedule Once the cause of the alarm is resolved and is acknowledged with OK the red indicator stops flashing The display will return to its normal display Ackn...

Страница 6: ...rve parallel displacement 5 30 adjustment 20 UTK function switched off see Advanced Service Level row 15 Curve higher value provides warmer temperatures for cold outdoor temperatures 20 60 adjustment...

Страница 7: ...time to stabilize UTK function switched off see Advanced Service Level row 15 Alternative temperature 15 15 C Adjustment See Outdoor temperature sensor and alternative heating in Electrical installat...

Страница 8: ...ut 2 1 4 2 6 3 8 4 10 5 12 6 14 7 kW Current 3 6 05 9 1 12 1 15 1 18 1 21 2 A 7 UTK function switched off see Advanced Service Level row 15 UTK min Limitation of the supply line temperature Adjustment...

Страница 9: ...16 above At Absolute temperature the selected temperature should not exceed 10 C 10 Manual activation of rows 19 and 20 Adjustment 0 Off 1 Limited to 15 minutes 0 Manual activation test run of output...

Страница 10: ...see Advanced Service Level line 14 For testing and service the connection delay and output connect disconnect can be temporarily sped up see Service level rows 1 and 2 The electric flow heater should...

Страница 11: ...few more times The pressure in a heating system varies with the temperature Do not add water unnecessarily Draining If the heating system needs to be drained of water the electric flow heater must fi...

Страница 12: ...ontain corrosion limiting additives Suitable water line quality Alkalinity 60 mg l to avoid corrosion Carbonic acid content 25 mg l increase the risk of corrosion Sulphate contents 100 mg l may accele...

Страница 13: ...and must be laid so that water pockets cannot form The opening pressure of the safety valve is determined by the component in the system that tolerates the lowest pressure System principles The figure...

Страница 14: ...conductor is connected in terminal 4 10 Electrical installation Electrical installation shall be carried out in accordance with the applicable regulations by an authorized electrical installer or by...

Страница 15: ...er 14 Overheating protection 15 Contactor power group three 16 Heating element output group three 8 4 kW 17 Heating element for output group two 4 2 kW 18 Heating element for output group one 2 1 kW W...

Страница 16: ...ain only when the temperature has dropped below the limit Selectable in Advanced Service level rows 16 and 7 Low boiler temperature Boiler temperature lower than 7 C The electric flow heater s tempera...

Страница 17: ...ard during resistance measurement When the boiler is energized voltage is measured in the sensor s connection points at the PCB Boiler temperature C k V C k V C k V 5 141 9 4 7 40 30 3 7 75 8 2 2 3 10...

Страница 18: ...tage size 2 1 kW Current stage 3 A Ingress protection rating IP x1 Flow requirements recommended t 10 C min max t 25 5 C 0 35 0 2 0 7 litres sec litres sec Pressure drop Volume 3 6 litres Design press...

Страница 19: ...panel 1 700414 Overlay 1 6 210206 Temperature sensor 1 11 440090 Capacitor 1 12 130010 Switch 1 120009 Knob for switch 1 700223 Shaft for switch 1 13 180023 Miniature circuit breaker 1 14 120025 Over...

Страница 20: ...V rmebaronen AB Arkelstorpsv gen 88 SE 291 94 Kristianstad Tel 46 44 22 63 20 www varmebaronen se www varmebaronen com info varmebaronen se...

Отзывы: