INSTRUCTIONS FOR USE
12
87-900-049-01 (E)
Controller Rear Panel
NOTE
The unit is provided with a Line Voltage selector. Refer
to the "INSTALLATION" paragraph of "TECHNICAL
INFORMATION" section for details about the Line
Voltage selection operation.
USE PROCEDURE
Controller Start-up
To start-up the controller, turn the main switch to ON,
after plugging the power cable into a suitable power
source.
Starting the Pump
The pump is activated only if the controller is powered
on and the pump itself is connected to the output
connector. For further information refer to the
“Technical Information” section.
Pump Shutdown
To shutdown the pump, turn the main switch placed on
the front panel to OFF.
MAINTENANCE
The MiniVac series controllers do not require any
maintenance interventions. Any intervention must be
performed by authorised personnel only.
When a fault has occurred it is possible to use the
Varian repair service or the “Varian advance exchange
service”, that allows to obtain a regenerated controller
replacing the faulty one.
!
Before carrying out any work on the controller,
disconnect it from the supply.
NOTE
Pins 3 and 7 on the loopback plug provided with the
unit are short circuited (Remote ON/OFF). This
loopback plug must be fitted to power on the HV unless
a Remote/Interlock contact is connected.
NOTE
The unit is factory set with a negative output polarity.
Refer to the section “Output Polarity Selection” for
instructions on how to change the output polarity.
If a pump is to be scrapped, it must be disposed of in
accordance with the specific national standards.
DISPOSAL
Meaning of the "WEEE" logo found in labels
The following symbol is applied in accordance with the
EC WEEE (Waste Electrical and Electronic Equipment)
Directive.
This symbol (
valid only in countries of the European
Community
) indicates that the product it applies to
must NOT be disposed of together with ordinary
domestic or industrial waste but must be sent to a
differentiated waste collection system.
The end user is therefore invited to contact the supplier
of the device, whether the Parent Company or a
retailer, to initiate the collection and disposal process
after checking the contractual terms and conditions of
sale.
WARNING!
1. Input module for the controller power supply. It
includes the protection fuse, the voltage changer, the
power supply plug, and the EMC filter (not included
into the plug/voltage switch assembly).
2. High voltage output connector for the pump (KINGS
or FISCHER type) power supply.
3. Input/output signal connector for fittings
1
3
2