9
PRODUCT 1 #
Product = 1, Push the UP Arrow to enter the
number of pumps for Product 1 – 1, 2, 3, or 4
Push
ENTER
–
NUM OF LEAD TURB
Define how many turbines can be lead
PRODUCT 1 #
Push
ENTER
–
NUM OF RUN TURB
Max number of turbines (lead or not)
PRODUCT 1 #
desired to run at a time
Push
ENTER
-
ROTATE TURBINES?
Select rotating or fixed lead turbine
PRODUCT 1 #
Choose either YES/NO
Push
ENTER
-
AUTO BASED
Method of pump staging for manifolded
AUTHORIZATION
applications. Use UP and DOWN ARROWS to set
correct option (
AUTO/INPUT/PRESSURE)
Auto – Energizes additional pumps after MLLD on
lead pump has passed the line
Input – Not used for the ISM-4080 system
Pressure – Not used for the ISM-4080 system
Push
ENTER
–
NUM SUCTION CV
0 is the default, only used for commercial suction
PRODUCT 1 0
pumps
Push
ENTER
–
NUM PRESSURE CV
0 is the default. If controlling transition valves,
PRODUCT 1 0
enter appropriate value
Push
ENTER
–
NUM DISPENSER CV
0 is the default, nearly always left at 0
PRODUCT 1 0
Push
ENTER
–
NUM OF TURBINES
This has moved back to get the same information on
PRODUCT 2 0
Product 2.
Push the UP Arrow to enter 1, 2, or 3 for the
number of pumps for Product 2
Pushing
ENTER
will cycle through subsequent Channels
Push
MENU
to return back to the Default screen, showing the normal scrolling screen such as:
PD=1 T=1L P=HI
MONITOR AL=N
If it is desired to temporarily disable scrolling to monitor a single channel, press the
ENTER
button on
the channel you wish to view. Pressing clear goes back to scrolling rotation, or the hold will timeout after
10 minutes.