Parameter
Description
Default value
Network dialing
number
The dialing number to access the specific cellular
network
*99#
APN
Access point name
3gnet
Authentication
mode
Auto: automatic mode
Auto
PAP: applying a two-way handshake to
authenticate client sessions
CHAP: applying a three-way handshake to
authenticate client sessions
PDP CID
The PDP CID used for establishing a connection
between a mobile device and a cellular network
1
PDP TYPE
The type of data transmission being used
IP
Network dial
username
Account for login the APN
Blank
Network dial
password
Password for login the APN
Blank
•
DTU Working Mode: information about the connection mode and network protocol
Parameter
Description
Default value
Connection mode
Long connection: uninterrupted communication
between the DTU and the data center
Long connection
Short connection: interrupted communication
between the DTU and the data center
Protocol
TCP: can retransmit data if packets fail to arrive
TCP
UDP: no data retransmitting. Lost data can’t be
retrieved
Send
authentication
Select to enable authentication or not
Disabled
•
Data Center: the cloud platform that the data is uploaded to. You can input the IP
a port number of the cloud platform for data uploading.