background image

Vantron 

| Embedded in your success, Embedded in your better life

 

World-leading provider of embedded/IoT products and solutions 

DE20-BT Industrial DTU | User Manual       

 

   

   

          www.vantrontech.com 

 

 
 
 

DE20-BT Industrial DTU 

 
 
 
 
 
 
 
 
 

User Manual 

 

Version: 1.2 

 

 

 

 

 

 

 

 

 

 

© Vantron Technology, Inc. All rights reserved.

Содержание DE20-BT

Страница 1: ...mbedded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual www vantrontech com DE20 BT Industrial DTU User Manual Version 1 2 Vantron...

Страница 2: ...of embedded IoT products and solutions DE20 BT Industrial DTU User Manual www vantrontech com Revision History No Description Date V1 0 First release Oct 19 2022 V1 1 Modified interface description as...

Страница 3: ...1 6 Power Supply and Consumption 11 CHAPTER 2 GETTING STARTED 12 2 1 Setting up the Device 13 2 2 Connectors and LED Indicators 15 CHAPTER 3 DEVICE PROVISIONING 17 3 1 Connecting a Field Device 18 3 2...

Страница 4: ...ns contained herein at any time without prior notice An up to date version of this manual is available at www vantrontech com The trademarks in this manual registered or not are properties of their re...

Страница 5: ...our question Product name and PO number Complete description of the problem Error message you received if any Vantron Technology Inc Address 48434 Milmont Drive Fremont CA 94538 Tel 650 422 3128 Email...

Страница 6: ...or otherwise modify the Product Such action may cause heat generation ignition electronic shock or other damages including human injury and may void your warranty Keep the Product away from heat sourc...

Страница 7: ...not use spray detergent Clean with a damp cloth Do not try to clean exposed electronic components unless with a dust collector Power off and contact Vantron technical support engineer in case of the f...

Страница 8: ...ntron Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 5 www vantrontech com CHAPTER 1 INTRODUCTIO...

Страница 9: ...ate carrier network CAT M and multiple data centers With such network protocols as PPP IP and TCP UDP supported real time device data is accessible and unvarnished transmission is feasible Thanks to i...

Страница 10: ...er should you find anything damaged or missing please contact your sales representative in due time Standard accessories Optional accessories 1 x DE20 BT DTU 1 x Power adapter with AC cable 1 x Blueto...

Страница 11: ...ED indicator 1 x 4G LTE status indicator 1 x Serial port status indicator 1 x Power indicator 1 x Error indicator Button 1 x Restore button Mechanical Dimensions 100mm x 74mm x 34mm Enclosure only Ins...

Страница 12: ...Embedded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 9 www vantrontech com 1 4 Product Layout 1 4 1 Top View Mounting bracket...

Страница 13: ...life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 10 www vantrontech com 1 4 2 Front View 1 4 3 Back View COM Power terminal Audio jack for conf Re...

Страница 14: ...ndustrial DTU User Manual 11 www vantrontech com 1 5 Mechanical Dimensions 100mm x 74mm x 34mm Enclosure only 1 6 Power Supply and Consumption DE20 BT industrial DTU works with 5V 36V DC power input s...

Страница 15: ...ron Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 12 www vantrontech com CHAPTER 2 GETTING STAR...

Страница 16: ...1 Setting up the Device Before you proceed with the configuration of your DTU follow the steps below to finish hardware connection 1 Position the device on a desired place for instance a wall or a de...

Страница 17: ...connectors and tighten the connectors round one to the BT connector flat one to the LTE connector 6 Use a DB9 male to 3 5mm serial adapter cable to connect the audio jack of the device to a host comp...

Страница 18: ...wer terminal of the device and the round end to the male end of the power cable 9 Plug the power adapter to a DC power outlet that meets the supply voltage requirement 5V to 36V to power on the device...

Страница 19: ...as PWR ERR 4G and RS232 485 The definition of the LED indicators is shown below LED Indicator Description PWR Solid green device powered on ERR Solid red device malfunction hardware error no SIM card...

Страница 20: ...n Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 17 www vantrontech com CHAPTER 3 DEVICE PROVISI...

Страница 21: ...connecting 2 Ensure you properly identify the screen printing of the pins on both the RS232 to RS485 adapter and the serial port of the DE20 BT For RS232 mode connect the RXD pin to TXD pin TXD pin t...

Страница 22: ...ial adapter cable to connect the device to the host computer sometimes a USB to RS232 female adapter might be needed 8 Power on the DTU Please note that the DuPont wires and RS232 to RS485 adapter fea...

Страница 23: ...the serial ports mapped in the host computer for illustrative purpose both the serial debug port and the serial communication port are connected to the host computer The actual COM number might be dif...

Страница 24: ...lated and unchangeable The username is admin by default with password as the password Another username is user and the password is the same 5 Make sure you have inserted an activated SIM card into the...

Страница 25: ...the Status menu to check the connection details Description of the numbered areas 1 The connection status between the DTU and the base station indicates whether the activated SIM card is properly inse...

Страница 26: ...the DE20 BT for data collection from a PLC sensor try to test if it works properly by connecting the serial communication port to a host computer other than a PLC sensor and use a serial debugging to...

Страница 27: ...and type certain characters in the text window 6 Check if the Uart Assistant receives data sent from the public TCP server 7 Check if the data sent from the serial port is received by the public TCP...

Страница 28: ...ata transmitted and received Network Layer information network mode data transmitted and received Application Layer information application center status 3 4 2 Configuration Under the Configuration me...

Страница 29: ...etooth sensors are supported Sensor ID Input the serial number of the Bluetooth sensor for data collection When there is data from the Bluetooth sensor the details are available in the Real Time Log m...

Страница 30: ...network 1 PDP TYPE The type of data transmission being used IP Network dial username Account for login the APN Blank Network dial password Password for login the APN Blank DTU Working Mode information...

Страница 31: ...l 28 www vantrontech com 3 4 3 DTU Management Firmware Upgrade 1 Select the bin file in the release package of the firmware 2 Click Upgrade after selecting the bin file and the application upgrade wil...

Страница 32: ...and solutions DE20 BT Industrial DTU User Manual 29 www vantrontech com Bluetooth Upgrade 1 Click the Bluetooth Upgrade menu under Firmware Upgrade 2 Upload the zipped upgrade file 3 The path and size...

Страница 33: ...export the settings for future use Action Description Perform Reboot The DTU will reboot upon a click of this button Export configuration To export current configurations of the Tool Import configurat...

Страница 34: ...To apply new pre set configurations to the Vantron Dtool 1 Click Import under Configuration Management in the Device Management menu 2 Select the json file and click Open 3 Confirm to import the new c...

Страница 35: ...ion Log Each action to the device will generate a log correspondingly and be displayed on the Operation Logs menu with a summarization of the total number at the bottom The logs could be cleared Real...

Страница 36: ...ntrontech com 3 4 5 Repair DTU When the device upgrade is unexpectedly interrupted or the firmware is corrupted the device connection might fail or the real time log will keep prompting CCCCC as follo...

Страница 37: ...dded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 34 www vantrontech com 4 Start repairing 5 If the process is stuck at 0 try to...

Страница 38: ...ce disconnected from the application center This is usually caused by invalid IP and port number of the data center Please check if the IP address and port number of the data center are valid and corr...

Страница 39: ...the device might also be off and the ERR indicator might be solid red To solve this issue eject the SIM card and re insert it to the SIM slot In certain cases the connection to the application center...

Страница 40: ...Embedded in your success Embedded in your better life World leading provider of embedded IoT products and solutions DE20 BT Industrial DTU User Manual 37 www vantrontech com CHAPTER 4 DISPOSAL AND WA...

Страница 41: ...to disposal in conformity with local regulations Please ensure that the abandoned batteries are disposed of according to local regulations on waste disposal Do not throw batteries into fire or put in...

Страница 42: ...to the CUSTOMER for non warranty repair VANTRON will provide this service as long as the components are available in the market and the CUSTOMER is requested to place a purchase order up front Parts r...

Страница 43: ...pment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or m...