10
Figure 3.4 LCD system configuration screen
3.3.2.
The following parameters are programmable:
Pre-delay:
number of seconds after a cycle is triggered, before RF energy
is activated. The maximum setting is 2.
NOTE:
The sealing head closes during the pre-delay.
EOS-delay:
number of seconds RF energy is activated. The maximum
setting is 5.
Post-delay:
number of seconds after RF energy is deactivated, before the
material is released. The maximum setting is 5.
NOTE:
The material cools during the post-delay. Releasing the material too soon can
affect the seal quality.
Clear counters:
reset the arc and cycle counters to zero. See 3.5.1.
Change password:
set a new password. See 3.5.2.
NOTE:
The arc and cycle counters remain visible during programming.
3.3.3.
To adjust the value of the pre-delay, EOS-delay, or post-delay, use the green
button to increment the value or the red button to decrement the value.
3.3.4.
Press and hold the green button to change to the next parameter. Press and
hold the red button to change to the previous parameter.
3.3.5.
Press and hold the green button and the red button at the same time to enter
the new values and return the generator to an idle state.