Page
17
Wiring Configuration
This thermostat should be wired by a licensed technician familiar with HVAC installation.
1
11
2
C
C ommon
12
3
13
4
F IL T E R
F ilter
P ower
(24VAC )
R
14
5
R S
O UT
O utdoor
S ens or
1's t
S tage
Heat
W1
15
6
R S
G ND
S ens or
G round
F an
G
16
7
R S
IND
Indoor
S ens or
1's t
s tage
C ooling
Y 1
17
8
X 2
C ommunication
2'nd
S tage
C ooling
Y 2
18
9
NC
No
C onnection
2'nd
S tage
Heat
W2
19
10 X 1
C ommunication
20
1
11
2
C
C ommon
12
3
F AUL T
Heat
P ump
F ault
13
4
F IL T E R
F ilter
P ower
(24VAC )
R
14
5
R S
O UT
O utdoor
S ens or
Auxiliary
Heat
E
15
6
R S
G ND
S ens or
G round
F an
G
16
7
R S
IND
Indoor
S ens or
1's t
S tageHeatP ump
Y 1
17
8
X 2
C ommunication
2'ndS tageHeatP ump
Y 2
18
9
NC
No
C onnection
C hangeover
Valve
O /B
19
10 X 1
C ommunication
20
C O NVE NT IO NA L
S Y S T E MS
(C ONV)
HE A T
P UMP
S Y S T E MS
(HP )
Содержание STAT
Страница 1: ...Vantage Communicating Thermostat AW000084 D...
Страница 31: ...Page 31 Wiring to Q ETS3 or STHERR101...
Страница 36: ...Page 36...
Страница 37: ...Page 37...