Transformer Ration Analysis Software Manual
12
4.0 USING THE PROGRAM
The users can now use the program to create test plans, run tests, and retrieve test records stored in the
ATRT-03 memory. Each of the menu options and sub options will be described in the following
sections.
4.1 Calculator
The “Calculator” option is used to quickly calculate the turns winding ratio of a transformer. To access
the calculator, select the calculator option of the “File” menu. It displays the calculator dialog box
shown in Figure 7. To use the calculator, type in the H voltage, X voltage and select transformer type.
Click on the “Calculator” button to get the ratio.
The percent option allow the user to calculate turn ratio at a percentage based on the name plate
voltages.
Figure 7. Calculator Menu
NOTE
The above figure shows H name plate voltage of 12,000 V and X name plate voltage of 1200
V. The transformer type is single phase, the turn ratio should be calculated as follows:
Ratio = (V
H
)/(V
x
) = 12000/1200 = 10
Since the “Percent” setting is 80%, the ratio is now changed to:
Ratio = 10 x 80% = 8.00
Содержание ATRT-03
Страница 28: ...Transformer Ration Analysis Software Manual 28 Figure 23 Create a Transformer Test Plan Menu 6 ...
Страница 31: ...Transformer Ration Analysis Software Manual 31 Figure 25 Create a Test Plan for a Load Tap Changer Menu 2 ...
Страница 40: ...Transformer Ration Analysis Software Manual 40 Figure 33 Run a Transformer Test Using a Test Plan Step 6 ...