Configuration
© Vanderbilt 2016
40
4.
Text
Enter a text for the alarm message.
Max. 22 characters can be entered.
5.
Audio Output
When "ON" is selected, an audio alarm message will be sent to an exter-
nal speaker.
A speaker with integrated amplifier inside has to be connected to the AUDIO
out jack.
6.
Event
Select an event.
Pre-recorded voice files with the extension .wav that have been uploaded
to the SD memory card can be selected as alarm messages. Up to 10 au-
dio sources can be selected.
External digital inputs 3
External digital inputs 3: All configurations are the same as those made for "ex-
ternal digital input 1, 2", except that input mode B/W is not available.
Motion detection settings
The settings are similar to those for alarm inputs, with some additional func-
tions:
1.
Motion Detection
Select "ON" to enable the motion detection function. Default setting: "OFF".
2.
Area
Click "Set Motion Area". An image screen will pop up. Select the target ar-
ea by dragging the mouse.
3.
Sensitivity
Choose different levels of 1~100 for sensitivity.
"1": Motion is activated with slight changes in brightness or motion.
"100": Motion is activated with big changes in brightness or motion.
4.
Object Size
Choose different levels of 1~100 for object size. Set the percentage area
size for a recognizable object.
"100%": Very large objects trigger motion.
"30%": Small objects trigger motion.
5.
Text Enable
When "ON" is selected, an alarm message will be displayed on the screen.
Содержание CFMW3025
Страница 1: ...Vanderbilt 2016 1 CFMW3025 3 Megapixel IP Indoor Dome Camera Configuration...
Страница 22: ...Installing the camera Vanderbilt 2016 22...
Страница 38: ...Configuration Vanderbilt 2016 38...
Страница 42: ...Configuration Vanderbilt 2016 42 Low Only large changes are detected...
Страница 52: ...Configuration Vanderbilt 2016 52 120 240 600 1200 1800 or 3600 s...
Страница 59: ...Configuration Vanderbilt 2016 59 Denied The listed IP addresses will be rejected by the firewall...
Страница 65: ...Configuration Vanderbilt 2016 65 9 10 7 Self Testing The status of the system can be displayed here...