FAS-402 Series Operating Instructions Ver. 4.06E
[ 01 ] SEALING ONLY
Change(number)
Change(item)
COUNTER
xxxxx
TEMP
MENU /
/ MENU=Back
1 Entry
2 Change
3 Delete
4 Maintain
MENU /
/ MENU=Back
1 Entry
2 Change
3 Delete
4 Maintain
( The cursor flashes )
[ 05 ] METHOD
Select
1 SEAL
2 VAC&SEAL
[ 05 ] METHOD
Select
1 SEAL
2 VAC&SEAL
( The cursor flashes )
[ 05 ] VAC TYPE
Select
VAC&SEAL
1 Manual 2 Time 3 Gauge
( The cursor flashes )
[ 05 ] VAC TYPE
Select
VAC&SEAL
1 Manual 2 Time 3 Gauge
( The cursor flashes )
[ 05 ]
Change
Move
VT 1 0.0sec
HT140
O
F 0.0s CT100
O
F
( The cursor flashes )
[ 05 ]
Change
Move
VT 1 0.0sec
HT 60
O
C 0.0s CT 40
O
C
( The cursor flashes )
8-2-2 Sample case: how to register the
“vacuum (timer) + seal”
operation
9
Select "2 Time" by pushing
,
buttons.
5
Select "1 Entry" by pushing
,
buttons.
7
Select "2 VAC&SEAL" by pushing
,
buttons.
11
Set the vacuum timer to 12.0seconds.
Refer to
“8-4-9 Set the vacuum time.”
3
Operation No.[01] is displayed
2
Turn ON the power switch
1
Turn ON the circuit breaker
4
Push the
button.
6
Push
button.
The display will show the following.
8
Push
button.
The display will show the following.
10
Push
button.
The display will show the following.
12
Use
button to set the heating temperature to
140ºC/280ºF.
Please refer to
“8-4-5 Set the heating temperature.”
13
Use
button to set the heating time to 0.3 sec.
Please refer to
“8-4-6 Set the heating time.”
14
Use
button to set the cooling temperature to
100ºC/200ºF.
Please refer to
“8-4-7 Set the cooling temperature.”
Let’s register "Vacuum timer" operation to the operation number [06].
Operation setting :
Heating temperature 140ºC/280ºF, Heating time 0.3 seconds, Cooling temperature 100ºC/200ºF
Vacuum time 12 sec.
TIPS
The following operation procedures are for the brand new machine without any change on the
setting.