SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
6
GENERATOR ELECTRIC CONTROLS
& OUTLETS
STARTING THE GENERATOR
WARNING
WARNING:
If the Generator will be used to
replace facility power in times of outages, the
facility power input must be isolated. Refer to the
Electric Generator Safety Precautions.
These connections must only be made by a licensed
electrician.
CAUTION
CAUTION:
This product contains, or
produces chemistries when it is used,
known by the Californian state that cause
cancer, severe defects of birth or other
damages. (Californian Code of Health and
Security 25249,5 et seq.).
STARTING THE UNIT
PRE-START PREPARATION
WARNING
WARNING:
This generator must not be
operated without heat shield installed in
factory. Failure to comply may cause the
fuel tank to overheat an result in personal
injury from fire.
WARNING
WARNING:
Gasoline is very dangerous.
Serious injury or death may result from fire
caused by gasoline contacting hot surfaces.
1. Do not fill the fuel tank with the engine
running.
2. Turn off the engine and wait 2 minutes before
filling the tank.
3. Do not spill fuel while refilling tank.
4. Do not mix oil with gasoline.
5. Follow all the instructions and warnings in the
engine manual.
DANGER
•
Provide adequate ventilation for toxic exhaust
gases and cooling air flow.
• Do not start or run the generator in an enclosed
area, even if doors or windows are open.
• Engines operation produces carbon monoxide, an
odorless, colorless, poison gas.
• Breathing carbon monoxide can cause nausea, fainting
or death.
1
2
3
4
5
6
7
All engines exhaust carbon monoxide, a deadly gas.
Breathing carbon monoxide can cause headaches,
dizziness, nausea, confusion and eventually death.
The carbon monoxide is colorless, odorless, tasteless gas
which may be present even if you do not see or smell any
engine exhaust. Deadly levels of carbon monoxide can
lay for hours or day in inclosed or poorly ventilated areas.
If you experience any symptoms of carbon monoxide
poisoning, leave the area immediately, get fresh air and
SEEK MEDICAL TREATMENT.
To prevent serious injury or death from carbon monoxide:
NEVER run engine indoors. Even if you try to ventilate
engine exhaust with fans or open windows and doors,
carbon monoxide can rapidly reach dangerous levels.
NEVER run engine in poorly-ventilated or partially enclosed
areas such as barns, garages, basements,carports, under
dwellings or pits.
NEVER run engines outdoors where engine exhaust can
be dawn into a building through openings such as windows
and doors
Before starting the generator, check for loose or missing
parts and for any damage which may have occurred
during shipment.
Check the oil level and fuel.
Disconnect all electrical loads from the unit.
Open fuel shut off valve.
Pull the choke ring to the end.
Set the engine switch to the “ON” position.
Turn the key switch to “START”. Release key switch after
the engine starts.
Push the choke ring to the original position.
CAUTION
Allow generator to run at no load for five
minutes after each initial start-up to permit
engine and generator to stabilize.
Содержание G120MG2200RV
Страница 1: ......
Страница 10: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 10 WIRING DIAGRAM ...
Страница 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 IDLE DOWN WIRING DIAGRAM ...
Страница 12: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 12 G120 G135 SPARE PARTS LIST ...
Страница 22: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 22 DIAGRAMA DE CABLEADO ...
Страница 23: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 23 DIAGRAMA DE CONEXION CONTROL DE VELOCIDAD ...