gum deposits during storage. The fuel additive can be
added to the fuel int the gas tank or put toguether to the
fuel in a storage container. The fuel and engine smoke
are flammable and potentially explosive. Use a suitable
procedure to store and handle fuel. Always have ABC
fire extinguisher nearby.
5-20P
L14-30P
ELECTRIC EXTENSIONS OR CORDS
All generator loads will be connected from the control
panel with extensions or cords with 3-prong grounded
plug for connection to120 volts outlet and 4-prong
grounded plug for connection to 120/240 volts outlets.
See Table 3 for select the minimum cable gauge of
extensions or cords in agreement with the necessities
of the loads.
When the load increases must be used a cable extension
of greater size. Using extensions of inadequate size it is
in where can result in serious problems with the voltage,
reducing the electric energy applied to the tools and
causing damage on them.
As far as smaller is the number of the wire gauge greater
is the conduction capacity, an example is that A wire
gauge 14 for example can lead a current higher than a
wire gauge16.
When several extensions are connected it is a must to
review that each extension is of the minimum gauge
required.
If you need to use an extension with outlets to connect
more than one electric tool, sum the amperes marked in
the nameplates of each tool to determine the minimum
cord gauge you need to use.
The extensions for 120 volts are made of 3 cables where
the green cable is the grounding one, the white cable is
the neutral and the black cable is the hot wire.
1
2
3
4
5
6
7
CAUTION
Do not overfill the tank. Keep maximum fuel
level to ¼ inch below the top of the tank.
This will allow for expansion during warm
weather, and so, avoiding spillage.
8
The extensions for exits of 120/240 are made of 4 cables
where the green cable is the grounding one, the white
cable is the neutral and the black and red cables are
the hot wires.
UNPACKING
GENERATOR SET UP AND CABLE
CONNECTIONS
1
2
3
4
When umpacking check to make sure that all parts are
included. Refer to the General Assembly Drawing and
Parts List at the end of this manual.
If any parts are missing or broken, please call our
distributor.
Place the generator outdoors where it will be used. This
must be a flat surface. and far from flamables materials.
Do not allow the generator gets wet.
Fill the tank fuel (outdoors) up to 6.0 gallon of gasoline,
do not fill the tank up to the top of tank.
After removing the plug with dipstick located in one
side of the engine, fill with 1.55 liter of oil. (Refer to the
engineo manual pag.5).
Before connecting the equipment to the generator
review that the equipment is Off. Read the section
DETERMINING TOTAL WATAGGE . Do not overload the
generator. Calculate the total power of the equipment.
The maximum power of the generator is indicated in the
specification sheet.
Содержание G120MG2200RV
Страница 1: ......
Страница 10: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 10 WIRING DIAGRAM ...
Страница 11: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 IDLE DOWN WIRING DIAGRAM ...
Страница 12: ...SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 12 G120 G135 SPARE PARTS LIST ...
Страница 22: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 22 DIAGRAMA DE CABLEADO ...
Страница 23: ...ESPECIFICACIONES SUJETAS A CAMBIO SIN PREVIO AVISO 23 DIAGRAMA DE CONEXION CONTROL DE VELOCIDAD ...