4. APPLIANCE DATA, EFFICIENCY AND NOx
4.1 General information.
The appliance information label is located on the burner tray on the left hand side of
the fire. This can be found by removing the Visual Baffle and Trim if fitted.
Page 11
©
GDC Group Ltd. AUG 2016
INSTALLER GUIDE
Models
600FS/600RC
800FS/800RC
Gas
Natural (G20)
Natural (G20)
FS/RC Input - Max (Gross)
6.0kW (20,473 Btu/hr)
6.4kW (21,838 Btu/hr)
FS/RC Input - Med (Gross)
3.2kW (10,918 Btu/hr)
3.3kW (11,260 Btu/hr)
FS/RC Input - Min (Gross)
2.4kW (8,189 Btu/hr)
2.4kW (8,189 Btu/hr)
Inlet Test Pressure (Cold)
20.0 +/- 1.0 mbar (8.0 +/- 0.4in w.g.)
20.0 +/- 1.0 mbar (8.0 +/- 0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Front Burner Injector
Cat 18 - 180
Cat 18 - 180
Rear Burner Injector
Cat 18 - 180
Cat 18 - 220
Pilot & Atmosphere Sensing Device
NG9093
NG9093
Ignition (RC)
Battery powered electronic remote
control & battery pack
Battery powered electronic remote
control & battery pack
Ignition (FS)
Electronic (Mounted on gas valve)
Electronic (Mounted on gas valve)