5.1.4

Install the supply pipe to run through the thick line

marked “

Supply pipe entry”

 and up to the inlet elbow

position.
Note that the centre of the appliance inlet elbow is 18mm
above the fireplace floor. The inlet elbow should be
removed from the appliance and fitted to the supply pipe at
this stage.
Remove the template. 

Note: If the supply pipe connection is to

be from the right side, keep the template, It will be useful for
bending the pipe later on (Section 8.4)

5.2

SIDE SUPPLY PIPE CONNECTION

The appliance is designed to allow a side supply pipe to run
in front of the front surround and through a cut- out at
either rear bottom corner of the fire front casting. For side
connection, final installation of the supply pipe should be
left until the appliance is installed in the fireplace.

6.

PREPARING APPLIANCE FOR

INSTALLATION

6.1

Remove the two screws securing the bottom of

the front surround to the sides of the convection box.
Raise the front surround to allow the retaining lugs at the
top to clear the slots in the convection box hood and then
lift clear (see figure 4).

6.2

Detach the burner unit from the convection box

by removing three screws (see figure 5). Lift the burner unit
clear.

6.3

Fit the two small "U" section seals to the bottom

edges of the convection box side flanges (see fig.6)

            

 

Fig. 4 Front surround removal

 

 

Fig. 5 Burner attachment points

 

Fig. 6 “U” seal positions

Содержание BR

Страница 1: ...06 02 MODEL BR417 G C 3 2 0 3 2 0 7 I n s e t L i v e F u e l E f f e c t G a s F i r e with U l t i m a t e or Superflame Front I N S T A L L E R G U I D E Please keep in a safe place for future refe...

Страница 2: ...all rates apply As supplied this appliance is for use with natural gas G20 When converted using Valor conversion kit no 591149 this appliance is for use with propane gas G31 These appliances are for u...

Страница 3: ...pipe installation 11 Preliminary burner checks 11 Reference pressure check 11 Ceramic coals walls installation 12 Full operating checks 13 Control settings check 13 Flue spillage check 13 Flame super...

Страница 4: ...nstallers CORGI requires its members to work to recognised standards The Confederation for the Registration of Gas Installers CORGI requires its members to work to recognised standards The installatio...

Страница 5: ...must be mounted behind a non combustible hearth n b conglomerate marble hearths are considered as non combustible The appliance can be fitted to a purpose made proprietary class O 150 C surround The...

Страница 6: ...r sealing tape 1 Flue restrictor plate 6 Fibre plugs 4 Woodscrews 2 Fire retaining cables 2 Cable clamps 4 Eyebolts 1 Installation template 1 Smoke match tube 1 Fire front casting 1 Bottom front cover...

Страница 7: ...or are sound enough to take the eyebolts and screws If these areas have deteriorated due to prolonged use they should be made sound with a suitable cement 4 2 3 Installations using a metal flue box Th...

Страница 8: ...and through a cut out at either rear bottom corner of the fire front casting For side connection final installation of the supply pipe should be left until the appliance is installed in the fireplace...

Страница 9: ...a concealed connection is being used insert the convection box into the fireplace feeding the supply pipe through the pierced hole in the rear seal 7 1 2 Mark the fireplace front surround through the...

Страница 10: ...10...

Страница 11: ...ainer over the bottom end of each cable 7 2 8 Pull each cable taut Push the cable retainers hard up against the V brackets Tighten the screws in the retainers so that they clamp the cables in position...

Страница 12: ...ition has been achieved keep the control knob depressed for approximately ten seconds to allow the thermocouple probe to warm up and then release it If the pilot does not remain alight ensure that the...

Страница 13: ...marked at the rear bottom corners L Left side R Right side Place the side walls against the sides of the fire box and in the recesses at the sides of the base coals The markings L R should be at the...

Страница 14: ...of the cross member figure 23 Keeping the neck of flared end in contact with the edge of the cross member slide the tube to the left until you feel it enter the notch in the edge of the cross member...

Страница 15: ...om of the appliance 11 6 Explain to the customer that the appliance has a flame failure spillage monitoring system Point out the explanation of this system shown in the owner s guide under Operating t...

Страница 16: ...hand plaque in position The left side of the plaque must touch the inside edge of the retaining flange at the left side of the burner well 12 1 6 Place the new right hand plaque in position Make sure...

Страница 17: ...12 4 6 Remove the second screw securing the pilot unit to the burner Remove the pilot unit and place it aside 12 4 7 Refit in the reverse order Note 1 The pilot unit must be replaced as a whole assemb...

Страница 18: ...are correctly engaged Check the operation of the tap 12 7 8 Refit the piezo generator 12 8 TO REMOVE THE MAIN BURNER INJECTOR 12 8 1 Remove the burner unit See section 12 3 12 8 2 Disconnect the main...

Страница 19: ...l knob 1 545979 E Pilot unit For Natural Gas Appliances 1 540979 Pilot unit For Propane Appliances 544929 F Burner plaque gasket set 1 569439 G Ceramic rear wall 1 545999 H Front coal halves 1 569449...

Страница 20: ...ards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our...

Отзывы: