Page 1: ...INSTALLATION INSTRUCTION Trimline 38 FS 1071 GBR IRL...

Page 2: ...9 5 INSTRUCTIONS FOR THE MERTIK MAXITROL GV60 10 6 GAS TECHNICAL SPECIFICATIONS 11 7 CONCENTRIC PATHWAYS 13 8 CONCENTRIC FLUE SYSTEM 14 8 1 Components of the concentric flue system 14 8 2 Indirect dir...

Page 3: ...eeds to be placed a minimum distance of 50mm from the wall unless stated otherwise in these instructions WARNING Gas fires become hot when in use After installation of the unit the glass surface is co...

Page 4: ...the lower part outwards Both the upper and lower covers can be removed These are attached with 4 hooks per cover Use the swivel legs to ensure the fireplace is level Adjust the height between the mant...

Page 5: ...become damaged 1 upwards 2 outwards 3 down to remove Removing the side glass panes To remove the side glass panes for replacement the upper and lower covers must be removed The side glass panes are fi...

Page 6: ...r 7 Concentric pathways contains a table that describes when a baffle plate and or a restriction must be put in place This is important to ensure the gas fire works correctly Before the lower cover is...

Page 7: ...e chips around the burner bed on the ventilation grid ensure even distribution here as well 2 Then put the ceramic wooden blocks into place as shown in the photo 3 4 5 6 7 8 9 J K Handle the blocks ca...

Page 8: ...4 6 8 5 7 9 11 10 B D E F G H C A Trimline 38 FS Installation instruction 8...

Page 9: ...ition control type B6R R8P Wifi Ready Ignition Remote control and Piezo ignition Gas connection 3 8 External A Gas inlet B Gas burner outlet C Thermocouple connection D pilot light burner connection U...

Page 10: ...ntenna wire and that they do not cross each other The high voltage released during ignition may damage the sensitive receiver circuit of the antenna This could mean the unit becomes less responsive or...

Page 11: ...ow position kW 2 6 2 6 3 1 3 1 NOx Hi classe 5 5 5 5 Efficiency class NE613 2 2 2 2 Useful return NCV system For nominal heat output 79 80 80 80 For minimal heat output 76 5 76 77 77 Supplementary ele...

Page 12: ...s NE613 2 2 Useful return NCV system For nominal heat output 79 79 For minimal heat output 72 6 72 6 Supplementary electricity consumption Nominal kWh 0 0 Stand by kWh 0 0 Energy efficiency Energy eff...

Page 13: ...om 2 meter Roof pass through with 90 slope E 1 12 0 3 From 2 meter 90 bend calculation length 2 metres length including roof or exterior wall outlets Always adhere to a starting length of 1 metre Rati...

Page 14: ...ant measures must be taken Determine the position of the unit and outlet and begin construction of the flue with the connection on the unit paying attention to the direction of installation and connec...

Page 15: ...e to the chimney coping watertight on the roof 8 using silicone sealant and stainless steel screws Install the roof pass through 9 and secure it in place using the supplied clamping strip 10 The slide...

Page 16: ...500 F Under a carport roof or balcony inside and outside corners 500 G From vertical ground pipes or drain pipes 300 H Inside and outside a corner 500 I Above an external gas pressure regulator 1000 S...

Page 17: ...bustion air supply circuit 2 The seal of the pressure hatches at the top and bottom of the fireplace check the gasket 3 Check of the pressure hatches above and below 1 2 3 Can they open and close free...

Page 18: ...end our thermoCet Cleaner Remove frame with glass pane See Paragraph 2 2 Preparation and placement on page 3 Important After the first use there will be a white haze on the inside of the glass pane th...

Page 19: ...head Check distance is approximately 4mm 5 Pilot light difficult to ignite Gas supply pressure too high nervous flame Adjust gas supply pressure or adjust the pilot light pressure using the gas valve...

Page 20: ...nings Check and clean with a vacuum cleaner or similar device Logs etc in wrong position Check and correct see instructions 11 Low main flame Gas supply pressure too low Check gas supply pressure and...

Page 21: ...190 618 385 1193 314 100 150 500 183 446 Trimline 38 FS Installation instruction 21 Appendix 1 DIMENSIONAL DRAWINGS Trimline 38 FS Mantle Measurements in mm...

Page 22: ...e Renovation package 7 Existing flue 9 Clamping strap 10 Roof pass through 1 Clamping strap 3 Clamping strap 4 Interior mounting plate Renovation package 5 Sliding element Renovation package 6 Flexibl...