18
12.6 TO REMOVE THE PIEZO
GENERATOR
12.6.1
Remove the gas tap as section 12.5.
12.6.2
Make sure that the tap is in the off position.
12.6.3
Remove the circlip holding the piezo unit to the
tap. Remove the piezo unit.
12.6.4
Replace in the reverse order.
12.7
TO GREASE THE CONTROL
TAP/F.S.D.
12.7.1
Detach the tap and remove the piezo generator
as section 12.6 making sure that the tap is in the off
position.
12.7.2
Remove the two screws from the head of the tap.
Remove the niting head and spindle complete with collar
and spring.
12.7.3
Note the position of the slot in the plug - mark
its position on the tap body.
12.7.4
Remove the plug rotating slightly while pulling.
12.7.5
Clean and grease the plug lightly with a suitable
grease. Do not apply excessive grease. Particularly, make
sure that the gas ports in the tap are not restricted by
grease.
12.7.6
Push the plug into the tap body and position the
slot in line with the mark previously made on the tap body.
12.7.7
Reassemble the niting head and spindle
complete with collar and spring making sure that the
components are correctly engaged. Check the operation of
the tap.
12.7.8
Refit the piezo generator.
12.8 TO REMOVE THE MAIN BURNER
INJECTOR
12.8.1
Remove the burner unit - See section 12.3.
12.8.2
Disconnect the main burner pipe from the
injector at the venturi end. If necessary, loosen the pipe at
the gas tap end to swing the pipe clear of the injector.
12.8.3
Unscrew the injector from the rear support
bracket.
12.8.4
Refit in the reverse order.
12.9
TO REMOVE THE APPLIANCE
FROM THE FIREPLACE
12.9.1
Remove the 5 loose coals, ceramic side walls, front
base coal, rear base coal and ceramic back wall.
12.9.2
Remove the front surround unit - See section
12.2.
12.9.3
If the appliance is fixed to the fireplace floor
remove the burner unit (See section 12.3) and
remove the two floor fixing screws.
12.9.4
If the appliance is attached by the front fixing
method (See section 7.1), remove the four screws
attaching the convection box side flanges.
12.9.5
If the appliance is fixed by the cable retention
method (See section 7.2), slacken the hexagonal
adjusters on the cable retainers and unscrew the
thumbscrews to release the cables.
12.9.6
Refit as described in the relevant installation
sections. Make sure gas soundness, sealing,
spillage test and performance are satisfactory.
13.
SHORT LIST OF SPARES
Содержание BR
Страница 10: ...10...