Operating the burner.
-
When the pilot burner is operating properly, gradually turn the control knob anti-
clockwise to 'HIGH' position. (Depress the knob slightly to get past the pilot ignition
position). The main burner should now light.
Depress the control knob slightly to release from the 'HIGH' position and turn back
(clockwise) to 'LOW'. While turning, the burner flames should gradually become lower
but remain alight. Depress the control knob slightly to release from the 'LOW' position
and turn back (clockwise) to the Pilot ignition position. The main burner should
extinguish but the pilot should remain alight. Depress the control knob slightly and
turn back (clockwise) to turn OFF. This will extinguish the pilot.
While cooling, the ceramic fuel effects may make some crackling noises. This is quite
normal.
Note i)
If the flames go out while setting the control, repeat the full lighting
procedure. If the flames repeatedly go out have the stove serviced.
ii)
Please note. When first turned on the flames will appear predominantly
blue. The fuel effect pieces will take time to warm up. Although some glow
will be seen after approximately ten minutes, the full visual effect will only
be apparent after a somewhat longer time.
iii)
The appliance will operate to its maximum potential if the flue is primed
during the first 20 – 30 minutes of operation. To do this, simply slide the
control button to its highest setting. This will also burn off any carbon
deposits that may have formed during previous operations.
iv)
If operating the appliance for long periods it is beneficial occasionally to
change the settings. This will also help to remove any carbon deposits
that may form during operation.
GAS CONSUMPTION
Model 910
Has a maximum natural gas input of 5.50kW (Gross)
Has a maximum natural gas output of 4.02kW
Has a minimum natural gas input of 2.3kW (Gross)
Has a minimum natural gas output of 1.68kW
Model 910 when converted using kit number 0591011
Has a maximum propane gas input of 5.40kW (Gross)
Has a maximum propane gas output of 3.94kW
Has a minimum propane gas input of 3.8kW (Gross)
Has a minimum propane gas output of 2.77kW