Checking the aeration setting of the burner.
(For LPG models refer to the conversion guide).
-
The aeration shutter is factory set. It is important to ensure
that the aeration setting is correct. Check the aeration shutter
setting (See figure 10).
-
To adjust the aeration setting, loosen the two aeration shutter
screws, slide the aeration shutter to the position shown in
figure 10 and tighten the fixing screws.
Page 18
©
GDC Group Ltd. 2014
INSTALLER GUIDE
Figure 10. Aeration