Valor Fires VALORFIRES 847 Скачать руководство пользователя страница 11

If fitting the firefront onto a reflective or shiny surface such as a hearth we
recommend that this surface does not extend further than 300mm from the fixing
plane (wall). Reflective or shiny surfaces that project further than 300mm may reflect
an image of the internal light source.

Securing the Firefront.

The firefront must be secured into position to prevent it from being tipped over.

The following securing options are available:

Method A

- Securing with wire.

Method B

- Securing with wire using an 

Optional

Spacer Frame kit 

(See section 3

).

If fitting the firefront onto a decorative hearth surface
such as marble or tile it is advisable to protect the
hearth surface. Do not drag the firefront as the surface
finish may be damaged.

Method A - Securing with wire.

1.

Supplied with the firefront is a spacer frame. The

opening for the Boiler Control should be on the right
hand side when fitting.

2.

Secure the spacer frame to the firefront using four

No.8 x 3/8 screws supplied (See figures 8 and 3).

3.

Insert the Boiler Control lead through the opening in

the spacer frame, then ensuring that the display is at
the top, gently push the Boiler Control into place. The
control will ‘click’ into place. Place the firefront in front
of the boiler, connect the Boiler Control lead to the
lead on the boiler and check the boiler operation.

INSTALLER GUIDE

Page 11

© 

Baxi Heating U.K. Limited 2009.

Figure 4. Fitting the spacer
frame to the firefront

Figure 5. Fitting the Boiler
Control.

Содержание VALORFIRES 847

Страница 1: ...eference INSTALLER AND OWNER GUIDE This guide is intended to help you install and care for your Valor Fires Electric Firefront Please read carefully before installing and using your firefront However...

Страница 2: ...K Limited The Wyvern Business Park Stanier Way Derby DE21 6BF Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims fo...

Страница 3: ...INSTALLER GUIDE Page 3 Baxi Heating U K Limited 2009 INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 17 TO 31...

Страница 4: ...tools 10 General notes to read before fitting your firefront 10 Where and how can you fit the firefront 10 Securing the Firefront 11 Method A Securing with wire 11 Method B Securing with wire using an...

Страница 5: ...to lift the firefront If for any reason this weight is considered too heavy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the w...

Страница 6: ...or cover the fan outlet or force items into firefront openings Never install or use the firefront anywhere where water or high humidity is in use i e Bathrooms Kitchens Shower Rooms and Swimming Pool...

Страница 7: ...ed Never connect the boiler and firefront to the same socket spur The fuse ratings are different and subsequent damage may occur 3 OPTIONAL KITS Although the firefront is supplied with a 50mm deep spa...

Страница 8: ...tents Quantity Illustrations are not to scale Firefront 1 Spacer frame 1 Only No 8 x 3 8 pan head screw 5 Tension wire 1 Eye screw 1 AAA Battery 2 Cable clamp 1 Handset 1 M4 x 25mm screw 2 Washer 2 Ny...

Страница 9: ...ver down on the rear of the handset and remove The polarity of the batteries is marked on the inside of the battery compartment If the firefront does not respond to the remote control handset commands...

Страница 10: ...urround using the optional spacer frame A The minimum rebate required is 45mm Q Do you want to fit the firefront against a flat wall with the base of the firefront on a hearth or similar surface A You...

Страница 11: ...isable to protect the hearth surface Do not drag the firefront as the surface finish may be damaged Method A Securing with wire 1 Supplied with the firefront is a spacer frame The opening for the Boil...

Страница 12: ...into the outside small hole on the right side of the firefront See point 1 figure 7 7 Thread the other end of the wire through the remaining small hole to the left Continue to push the wire through t...

Страница 13: ...u want the firefront to be fitted against a flat wall it will be necessary to purchase two kits they are designed to be secured together 1 There are four screws supplied with the optional spacer frame...

Страница 14: ...from its packaging 2 There are two magnets on the lower raised areas of the fascia See figure 10 Ensure that they are located correctly before fitting the fascia 3 Supplied with the fascia is a black...

Страница 15: ...g the Innova fascia 1 Remove the fascia from its packaging 2 There are two magnets on the lower rear of the fascia They should rest against the outer edge of the two raised sections See figure 12 Ensu...

Страница 16: ...ard 3 After completing work on the boiler fit the firefront and fascia as in sections 5 and 6 of this guide Dream model 1 Remove the lower casting and ash pan from beneath the fascia Unscrew and remov...

Страница 17: ...Page 17 Baxi Heating U K Limited 2009 OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 26 TO 31...

Страница 18: ...ith my firefront 24 3 CLEANING AND MAINTAINING THE FIREFRONT 24 4 ENVIRONMENT 25 5 WARRANTY AND SERVICE 26 CUSTOMER CARE Thank you for choosing Valor Fires All Valor Fires firefronts are designed to m...

Страница 19: ...press the red ON OFF button The status lamp on the firefront will turn red see figure 2 Pressing the LAMP button This turns the effect on The indicator lamp will flash green for approximately five se...

Страница 20: ...re 2 will flash green for approximately five seconds after this time the lamp will no longer be visible Press the button a second time This will turn the 1 kW heater on The effect will already be on T...

Страница 21: ...en if the system external controls timer programmer etc are requesting central heating or domestic hot water If the boiler is ON then the display on the Boiler Control will show a number this being th...

Страница 22: ...n lockout the display will show E1 alternating with 33 How to RESET the Boiler If an error code is displayed a manual reset operation may be required A list of error codes that can be reset are given...

Страница 23: ...working or not working correctly please check the following before calling Heateam Make sure the gas supply is turned ON Check if other gas appliances are working e g cooker If there is no gas contact...

Страница 24: ...nside of the battery compartment If the firefront does not respond to the remote control handset commands it is likely that the batteries are faulty or require replacement The firefront can be operate...

Страница 25: ...l with your call quicker and avoid you having to make a second call Your Post Code The fault problem or request Model Name and serial number This information can be found on a small label attached to...

Страница 26: ...e a fault with your new boiler or firefront we aim to provide a safe and high quality repair service supported by our dedicated national network of highly skilled engineers If your installer can t res...

Страница 27: ...e installation instructions supplied with the boiler this includes the need to flush the system effectively and add a suitable corrosion inhibitor Any damage caused by hard water scale deposits and or...

Страница 28: ...Page 28 Baxi Heating U K Limited 2009 OWNER GUIDE...

Страница 29: ...Page 29 Baxi Heating U K Limited 2009 OWNER GUIDE...

Страница 30: ...istration Number Company Name Company Address Company Telephone number Company Fax number A LABEL CONTAINING THE BOILER SERIAL NUMBER MAY HAVE BEEN PLACED INSIDE THIS BOX Boiler Model B A X I B E R M...

Страница 31: ...abel See figure 7 A LABEL CONTAINING THE FIREFRONT SERIAL NUMBER MAY HAVE BEEN PLACED INSIDE THIS BOX Brand Please tick Baxi Valor Wonderfire Other D D M M Y Y Date of Installation Figure 7 A LABEL CO...

Страница 32: ...Baxi Heating U K Limited 2009...

Отзывы: