Operating the fire WITHOUT the Remote Control Handset.
Lighting the burner in the event of battery failure.
1.
To gain access to the gas valve gently pull and lift the bottom front cover
(See figure 2).
2.
The ‘main valve knob’ is the knob on the right
hand side (See figure 3). Turn this knob to the
‘OFF’, fully clockwise position
.
3.
The ‘manual knob’ is the knob on the left
hand side (See figure 3). Turn this knob to the
‘OFF’, fully clockwise
position.
4.
Place the ‘ON/OFF’ switch to the ‘O’ (Off
position).
5.
Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor. If
you smell gas STOP! and follow the safety
information below.
!
DON’T SMOKE.
!
EXTINGUISH ALL NAKED FLAMES.
!
DON’T TURN ELECTRICAL SWITCHES ON OR
OFF.
!
TURN OFF THE GAS SUPPLY AT THE METER.
!
OPEN DOORS AND WINDOWS TO GET RID
OF THE GAS.
!
IMMEDIATELY CALL THE GAS EMERGENCY
SERVICE FROM A NEIGHBOURS PHONE -
SEE YOUR LOCAL TELEPHONE DIRECTORY.
!
If you do not smell gas, proceed as
below.
6.
Place the ‘ON/OFF switch to the ‘
-
’ (On position).
7.
With the ‘manual’ knob in ‘MAN’ position a manual
pilot valve operator is accessible (See figures 3 & 4).
!
Fully push down the manual pilot valve operator
using the end of a pencil or similar and hold in, to
start pilot gas flow. Immediately light the pilot with a
match, while continuing to hold in the manual pilot
valve operator for about ten (10) seconds after the
pilot is lit. Release manual pilot valve operator. If
pilot does not stay lit, repeat steps 2 through 7.
NOT:
If the pilot does not stay lit after several
tries, turn the gas control knob (main valve knob) to ‘OFF’ and proceed to step 10.
8.
Turn the ‘manual’ knob to the ON, full counterclockwise
position. The main
Page 43
©
Baxi Heating U.K. Limited 2007.
Figure 4. Pilot valve operator
Figure 3. Controls
Figure 2. Bottom front access cover
OWNER GUIDE
Содержание 757
Страница 14: ...Page 14 INSTALLER GUIDE Baxi Heating U K Limited 2007 Figure 5 Appliance dimensions and clearances...
Страница 16: ...Page 16 INSTALLER GUIDE Baxi Heating U K Limited 2007 Figure 6 Pack contents...
Страница 26: ...Page 26 INSTALLER GUIDE Baxi Heating U K Limited 2007 Figure 27 Hanging bracket locations...
Страница 48: ...Page 48 Baxi Heating U K Limited 2007 OWNER GUIDE...
Страница 49: ...Page 49 Baxi Heating U K Limited 2007 OWNER GUIDE...
Страница 52: ...Baxi Heating U K Limited 2007...