4FXM70EN - 8/2022
Description of Relay and Contact Closure Output triggers
Selection
Contact energizes when
Pump Run/Stop
Motor turning (roller assembly is rotating).
Monitor Input
Incoming analog or digital signal is not received or is
out of range.
Monitor Output
Outgoing analog or digital signal not transmitted or is
out of range.
Monitor Run/Fail
Motor fails to respond to commands from the internal
controller.
Both TLD/FVS
Either TLD or FVS system triggers.
FVS
After the programmed delay time, pulses are not
received from flow sensor.
TLD
Tube leak is detected by sensors in the head.
Active Mode
The selected run mode is currently activated.
Remote Active
Energized when Remote only is activated.
Reverse Alarm
The motor revolution is reversed (turning clock-wise).
General Error
A motor overload or other internal error has occurred.
Disable
Output alarm contact is disabled.
5.1 Signal Output
Sends a configurable 4 - 20 mA or frequency (Hz) signal to
another pump or external device. This feature can be used to
control other pumps (in sync / proportionally), data logging
systems, and other external devices for plant automation.
Output Setup menu structure, see page 39.
Default settings: Disable
Navigate to
Signal Output
menu by pressing MENU button,
then selecting Output Setup, and then
Signal Output
.
Select your desired Signal output using UP or DOWN
arrows.
Press ENTER to configure output signal.
Press UP or DOWN arrow to scroll through 0 - 9 on selected
digit.
Press RIGHT arrow to scroll over to next digit to right. If
you pass your desired digit, you can easily scroll back by
continuously pressing RIGHT button.
Press ENTER to save changes.
Continue this process until all four screens have been
configured.
To navigate back out of menu structure you must select ←OK
at bottom of every screen menu until you see Run Mode
screen displayed.
Содержание Flowrox FXM Series
Страница 11: ...11 4FXM70EN 8 2022 2 2 Dimensions Dimensions in mm inches in parenthesis FXM2 FXM3 ...
Страница 14: ...4FXM70EN 8 2022 14 2 5 WIRING TERMINALS AND I O SCHEMATICS Connector box layout ...
Страница 18: ...4FXM70EN 8 2022 18 3 2 Configuration Menu Below is menu structure for Configuration screens ...
Страница 23: ...23 4FXM70EN 8 2022 4 Input Setup Below is the menu structure for the INPUT SETUP selection ...
Страница 24: ...4FXM70EN 8 2022 24 ...
Страница 41: ...41 4FXM70EN 8 2022 11 10 9 8 7 6 5 1 4 3 2 1 5 ONLY WITH 3 8 TUBE NUT CONNECTORS ...
Страница 43: ...43 4FXM70EN 8 2022 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 45: ...45 4FXM70EN 8 2022 ...