19
4FXM70EN - 8/2022
Language Selection
Press MENU button to enter menu structure for setting up
pump.
Select Configuration and Press ENTER button.
Select Display Language and Press ENTER button.
Select your desired language, then Press ENTER.
Select OK at bottom of list to confirm your selection. Press
ENTER button.
Select ←Back on following screens to move back up to desired
menu location.
Set Password
Press MENU button to enter menu structure for setting up
pump.
Select Configuration and Press ENTER button.
Select Set Password and Press ENTER button.
Set your desired number, then Press ENTER.
Note: Default is 0000.
Select Yes at bottom of list to confirm your selection. Press
ENTER button.
Select ←Back on following screens to move back up to desired
menu location.
Set Trigger Level
The FXM is equipped with a non-contact Tube Leak
Detection (TLD) System which is designed to stop pump
and provide an output alarm (see Output menu) in the event
pump tube should rupture and chemical enters pump head.
System is capable of detecting presence of a large number
of chemicals including Sodium Hypochlorite (Chlorine),
Hydrochloric (muriatic) Acid, Sodium Hydroxide, and
many others. System will not be triggered by water (rain,
condensation, etc.) or silicone oil (roller and tubing
lubricant).
If system has detected chemical, pump tube must be replaced
and pump head and roller assembly must be thoroughly
cleaned. Failure to clean the roller assembly will void
warranty.
If TLD alarm occurs, pump will stop, close an alarm output
(if configured), and screen will flash TLD with an alarm icon.
Leakage Trigger Level setting:
Press MENU button to enter menu structure for setting up
pump.
Select Configuration and Press ENTER button.
Select Set Trig. level and Press ENTER button.
Setting scale is 1-40. Set your desired number for Leakage
Trigger setting, then Press ENTER. Factory setting is 12.
Select ←Back on following screens to move back up to desired
menu location
Содержание Flowrox FXM Series
Страница 11: ...11 4FXM70EN 8 2022 2 2 Dimensions Dimensions in mm inches in parenthesis FXM2 FXM3 ...
Страница 14: ...4FXM70EN 8 2022 14 2 5 WIRING TERMINALS AND I O SCHEMATICS Connector box layout ...
Страница 18: ...4FXM70EN 8 2022 18 3 2 Configuration Menu Below is menu structure for Configuration screens ...
Страница 23: ...23 4FXM70EN 8 2022 4 Input Setup Below is the menu structure for the INPUT SETUP selection ...
Страница 24: ...4FXM70EN 8 2022 24 ...
Страница 41: ...41 4FXM70EN 8 2022 11 10 9 8 7 6 5 1 4 3 2 1 5 ONLY WITH 3 8 TUBE NUT CONNECTORS ...
Страница 43: ...43 4FXM70EN 8 2022 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 45: ...45 4FXM70EN 8 2022 ...