background image

VALLOX DIGIT SE  has been initially adjusted
for normal circumstances in your home. Venti-
lation adjustment is needed mainly in the
following circumstances:

1. 

THREE QUESTIONS ABOUT VENTILATION

1.1.  Why are rooms ventilated? ............................................................ p. 3
1.2.  What are the characteristics of adequate ventilation? ........................ p. 3
1.3.  How much ventilation is needed? .................................................... p. 3

2. 

INSTRUCTIONS FOR USE: VALLOX DIGIT SE

2.1.  Taking into use  ............................................................................. p. 4
2.2.  Ventilation control.......................................................................... p. 4
2.3.  Ventilation control with control panel................................................ p. 4
2.4.  Ventilation control with CO2 sensor ................................................. p. 5
2.5.  Ventilation control with humidity sensor ............................................ p. 5
2.6.  Ventilation control with voltage or current signals............................... p. 5
2.7.  Ventilation control with remote monitoring system .............................. p. 5
2.8. Post-heating .................................................................................. p. 

5

2.9.  Supply air constant temperature control ...........................................

p.

2.10.  Supply air cascade control ............................................................. p. 6
2.11.  Heat recovery bypass .................................................................... p. 6
2.12.  Heat recovery cell defrosting function............................................... p. 6
2.13.  Maintenance reminder ................................................................... p. 7
2.14.  Filter guard function ....................................................................... p. 7
2.15.  Anti-freezing of the water circulated post-heating radiator................... p. 7
2.16.  Fireplace switch / boosting function................................................. p. 7
2.17.  Fault signalling relay...................................................................... p. 7
2.18.  Air filtration .................................................................................. p. 7

3.

CONTROL PANEL

3.1.  Instructions for use ......................................................................... p. 8
3.2.  Operating menu............................................................................ p. 8
3.3.  Settings menu................................................................................ p. 9
3.4.

Week clock control ........................................................................p. 11

3.4.  Factory settings .............................................................................p. 12

4.

INSTRUCTIONS FOR MAINTENANCE

4.1. Filters ...........................................................................................p. 

13

4.2.  Fans and post-heating radiator........................................................p. 14
4.3.  Filter guard ...................................................................................p. 14
4.4.  Condensing water .........................................................................p. 13

5.

TROUBLESHOOTING

...................................................................................p. 16

VALLOX DIGIT SE/SE VKL

TABLE OF CONTENTS

2

2

VALLOX DIGIT SE models

Code: B3500 SE

VALLOX DIGIT SE

• Post-heating radiator: electric radiator 1000 W

ALLOX DIGIT SE VKL

• Post-heating radiator: water radiator

• Letter L or R after the name of the unit indicates whether the unit

is left- or right-handed.

EVERYDAY QUICK GUIDE

NOTE!
Never switch ventilation off,
because ventilation keeps indoor air
quality uniform and removes gases
and dust emanating from the
structures.

•  Taking a bath:

Boost ventilation in bathing and washing
facilities in order to ensure that the rooms
get dry as quickly as possible. It is advisab-
le to have boosted ventilation on for 2 to 3
hours after taking a sauna bath, unless au-
tomatic adjustment based on humidity con-
tent is used.

•  Washing and drying clothes:

Boost ventilation in washing and drying
rooms during the activity, unless automatic
adjustment based on humidity content is
used.

• Sleeping:

Ventilation in a bedroom has to be suffi-
cient throughout the night. The level is cor-
rect when air does not smell fusty when
you enter the room in the morning. If the
carbon dioxide content of a room is moni-
tored and ventilation is adjusted according-
ly, air will always be fresh.

• Empty dwelling:

To save energy, ventilation can be adjusted
to the minimum level.

• Cooking:

If the ventilation unit is connected to a coo-
ker hood, boost ventilation during cooking.

The most common way to abate coo-
king fumes is to have a separate
cooker hood.

© VALLOX • We reserve the right to make changes without prior notification.

Содержание DIGIT SE

Страница 1: ...ONTROLLER WITH LCD DISPLAY 1 09 61E 27 5 2008 CODE B 3500 SE VALLOX VKL INSTRUCTIONS FOR USE AND MAINTENANCE MODELS VALLOX DIGIT SE VALLOX DIGIT SE VKL VALLOX We reserve the right to make changes with...

Страница 2: ...ing water p 13 5 TROUBLESHOOTING p 16 VALLOX DIGIT SE SE VKL TABLE OF CONTENTS 2 2 VALLOX DIGIT SE models Code B3500 SE VALLOX DIGIT SE Post heating radiator electric radiator 1000 W ALLOX DIGIT SE VK...

Страница 3: ...hroom and the sauna get dry quickly During the heating season the windows and other outer wall structures remain dry Humidity in indoor air is not condensed in the ventilation ducts Air is fresh in th...

Страница 4: ...ventilation 2 2 Ventilation control The unit can be fully controlled with the control panel delivered with the unit or with an optional LON converter The standard week clock control can be used to con...

Страница 5: ...e basic and maximum fan speeds set When the unit is taken into use for the first time with automatic setpoint search selected factory setting it will take the program 3 10 hours to determine the value...

Страница 6: ...ssible To do this the heat recovery bypass function compares the measurement data of the outdoor and extract air sensors The heat recovery cell is bypassed when the post heating function is off when o...

Страница 7: ...ireplace for instance The function is activated by pressing a self resetting push button switch On each pressing of the switch the stopping function goes on for 15 minutes During the function the fire...

Страница 8: ...on 3 1 items 5 and 6 in the figure To settings menu See manual RH1 35 RH2 40 CO2 0821 PPM Out 20 In 20 Sup 20 Exh 20 Temp setting 20C 5 Scrolling up With this button you can scroll the displays upward...

Страница 9: ...ings see manual The adjustment interval for humidity and carbon dioxide adjustments is selected with the and buttons The adjustment interval refers to minutes 3 3 9 Adjustment interval Adjust interval...

Страница 10: ...ired cell bypass temperature is selected with the and buttons If outdoor temperature is lower than cell bypass temperature the summer winter damper is in the winter position 3 3 15 Changing the operat...

Страница 11: ...e word Exit and pressing or Changes in fan speed Sp and supply air temperature Tmp are only made for the hours desired in other cases use N no change to previous Monday D 1 07 00 hours H 7 fan speed 2...

Страница 12: ...nt CO2 900 ppm CO2 Basic humidity level value chosen either automatically or manually Adjustment interval 10 min Freezing protection cell 4 C Freezing protection hysteresis 3 C Preheating setpoint 6 C...

Страница 13: ...of filters The G3 coarse filter A filters insects and coarse pollen and dust The F7 fine filter B filters fine dust that is not discernible to the eye Extract air is filtered with a similar G3 filter...

Страница 14: ...Self actuated one way dampers are only used in VKL model units Observe the position of the damper so that it can also operate on the F7 filter side 4 3 Filter guard DIGIT SE can be equipped with an o...

Страница 15: ...m peratures by 1 or 2 C It extends the period between stop ping and starting See the instructions for using the control panel Section 3 3 22 If the preheating radiator does not operate check if over h...

Страница 16: ...glass tube fuse located in the control card behind a protecting plate the electronics inside the unit may have blown 12 Check the door switch and fuses The unit includes a T800 mA glass tube fuse If...