EXTERNAL ELECTRICAL CONNECTION TO THE VENTILATION UNIT 

OR A ROOF FAN

ALARM

TACHO

GND

0-11V

PIEZO
+   -

DAMP
IN OUT

MODE
IN OUT

F ALARM

  RS 485
A  B GND

N

L

DAMPER

1    2    3

LIGHT

N    L

FAN

N    L

EC roof fan

Tacho

-

S

MC 

VENTILATION UNIT

Five terminal 

connector**

GND

S

GND

S

MC 

VENTILATION UNIT

Four terminal 

connector

MV 

VENTILATION UNIT

GND

AN/I

RM/I

RM/O

E/I

LED / E/O

PROGRAMMING 

CONNECTORS OF 

THE MOTHERBOARD

CONTACT DATA:

GUARD FUNCTION:

NORMAL SITUATION = OPEN

ACTIVATED = CLOSED

HOUSE AUTOMATION:

NORMAL SITUATION = OPEN

ERROR SITUATION 

(HOOD OR VENTILATION UNIT) = CLOSED

ACTIVATED GUARD FUNCTION = FLASHING

POSITION OF THE DAMPER:

DAMPER CLOSED = CONTACT OPEN

DAMPER OPEN = CONTACT CLOSED

* External error data is connected in the place 

  of the short circuit link of the mother board

** Disconnect the short circuit link between connectors 

    3 and 5 from the MC unit’s control panel connector

IN OUT

PE

EXTRA

DAMPER POSITION

CONTACT DATA

GUARD FUNCTION

CONTACT DATA

HOUSE AUTOMATION

CONTACT DATA

3 POTENTIAL  FREE CONTACT 

DATA 24VDC/5A

*HUOM!

DIMENSION DIAGRAMS

 498 / 598 

 80 

ø 125 Female

 265 / 315 

 93 

 63 

 289 

 101 

 510 

 305 

 154 

Содержание Delico PTD EC

Страница 1: ...pe A279843 1 Vallox DelicoPTD EC The Vallox Delico PTD EC control hood is suited to controlling EC roof fans and Vallox ventilation units The cooker hood is designed to be used above the cooker top as...

Страница 2: ...the light switch The light is dimmable Adjust the brightness by pressing the light switch until the brightness is adequate Ventilation modes Select the ventilation mode by pressing the ventilation mo...

Страница 3: ...lation unit turns off and the damper closes If this kind of alarm is noticed before fire damage it can be acknowledged by pressing any of the cooker hood buttons Pre selection of light brightness To m...

Страница 4: ...ooker fan must be easy to access CAUTION The cooker hood must not be connected to a flue that is used for removing combustion gases e g from a wood or gas burning fireplace cooker or stove CAUTION Reg...

Страница 5: ...RD FUNCTION NORMAL SITUATION OPEN ACTIVATED CLOSED HOUSE AUTOMATION NORMAL SITUATION OPEN ERROR SITUATION HOOD OR VENTILATION UNIT CLOSED ACTIVATED GUARD FUNCTION FLASHING POSITION OF THE DAMPER DAMPE...

Страница 6: ...mum voltage of 10 VDC Next press the ventilation mode button which sets the control voltage at 2 5 VDC After this the voltage will increase by 0 5 VDC at a time Save the selected control voltage by pr...

Страница 7: ...dp dp 2 x Boost ventilation The volume flow rate of the air inside the cooker hood is measured with the damper open based on the static pressure loss and the performance scheme of the cooker hood Meas...

Страница 8: ...Vallox DelicoPTD EC D9517 18 12 2020 www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Technical support 358 10 7732 270...

Отзывы: