VENTILATION CONTROL

It is recommended that ventilation be left turned on 

during long holidays also. This keeps the indoor air 

fresh and prevents humidity from condensing in the 

ventilation ducts and structures. It also reduces the risk 

of moisture damage. 

USING THE COOKER HOOD

The cooker hood has a sliding part that can be pulled 

out of the cooker hood. Pull the sliding part out of the 

cooker hood for maximal extraction capacity.

  Position of the damper

The damper is opened by pressing the damper button 

(light turns on). The damper is closed (light turns off) by 

pressing the damper button or automatically after one 

hour (without a timer or 45-120 min when programmed).

 

In normal circumstances, the damper must be closed 

(the signal light is off), which boosts the extract air flow 

from other premises.

The damper must be open

 (the signal light is turned on) 

when the user wants to increase the extract air flow 

from the cooker hood

 e.g.

•  when the cooker top or the oven is used for 

cooking

•  when the load in the kitchen is exceptional e.g. due 

to the use of strong detergents or the presence of 

a large number of people.

Front panel buttons

The front panel of the cooker hood has four buttons 

and four signal lights.

  Cooker hood light

Turn the light on or off by pressing the light switch. The 

light is dimmable. Adjust the brightness by pressing the 

light switch until the brightness is adequate.

  Ventilation modes

Select the ventilation mode by pressing the ventilation 

mode button repeatedly until the signal light indicates 

the desired mode:

  Away 

  At home

  Boost

Selection button

The selection button is roughly 3 cm to the left from the 

damper button. The selection button is not marked on 

the front panel.

 

Away

  The ventilation efficiency can be 

temporarily reduced when the apartment 

is unoccupied. 

 

At home

  Ventilation must be continuous, i.e. the air 

inside the building must be replaced at 
least once every two hours.

 

Boost

 

 

Cooking, sauna, bathing, drying of 

clothes, excessive heat, and other similar 

situations can require that ventilation 

be increased from the standard setting. 

In such a situation, ventilation must be 

increased.

CAUTION

•  Neglecting the cleaning of the grease 

filter can cause a fire hazard.

•  The outer surfaces of the hood can 

become hot when the cooker or the 

oven is turned on.

•  Flaming is forbidden underneath the 

cooker hood.

•  Always follow the instructions 

provided on adjusting the efficiency of 

ventilation.

•  Enable a sufficient supply air flow 

into the room if the cooker hood 

and non-electric devices are used 

simultaneously.

Apartment-specific ventilation units allows residents to 

adjust the ventilation efficiency. Ventilation is controlled 

based on the need e.g. through the cooker hood, 

ventilation control panel, or a separate control centre.

Содержание Delico PTD EC

Страница 1: ...pe A279843 1 Vallox DelicoPTD EC The Vallox Delico PTD EC control hood is suited to controlling EC roof fans and Vallox ventilation units The cooker hood is designed to be used above the cooker top as...

Страница 2: ...the light switch The light is dimmable Adjust the brightness by pressing the light switch until the brightness is adequate Ventilation modes Select the ventilation mode by pressing the ventilation mo...

Страница 3: ...lation unit turns off and the damper closes If this kind of alarm is noticed before fire damage it can be acknowledged by pressing any of the cooker hood buttons Pre selection of light brightness To m...

Страница 4: ...ooker fan must be easy to access CAUTION The cooker hood must not be connected to a flue that is used for removing combustion gases e g from a wood or gas burning fireplace cooker or stove CAUTION Reg...

Страница 5: ...RD FUNCTION NORMAL SITUATION OPEN ACTIVATED CLOSED HOUSE AUTOMATION NORMAL SITUATION OPEN ERROR SITUATION HOOD OR VENTILATION UNIT CLOSED ACTIVATED GUARD FUNCTION FLASHING POSITION OF THE DAMPER DAMPE...

Страница 6: ...mum voltage of 10 VDC Next press the ventilation mode button which sets the control voltage at 2 5 VDC After this the voltage will increase by 0 5 VDC at a time Save the selected control voltage by pr...

Страница 7: ...dp dp 2 x Boost ventilation The volume flow rate of the air inside the cooker hood is measured with the damper open based on the static pressure loss and the performance scheme of the cooker hood Meas...

Страница 8: ...Vallox DelicoPTD EC D9517 18 12 2020 www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Technical support 358 10 7732 270...

Отзывы: