INSTALLATION

4

3

MANU

AL

7

8

1.

2.

3.

1

2

L = Left

5

R = Right

Install the right mounting  

strip similarly to the left.

ø 125 mm 

duct

connector

CAUTION

The minimum distance 

of the bottom edge of 

the hood to an electric 

cooker is 500 mm and 

to a gas cooker 650 

mm.

CAUTION

The power outlet used 

for the cooker fan must 

be easy to access.

CAUTION

The cooker hood must 

not be connected to 

a flue that is used for 

removing combustion 

gases (e.g. from a 

wood- or gas-burning 

fireplace, cooker, or 

stove).

CAUTION

Regulations on leading 

extraction air outdoors 

must be observed.

 293 - 310 

 311 - 333 

 20 

 45 

Where needed, install a cover strip behind the cooker hood to 

cover the opening.

6

9

Adjust the glass of 

the front panel to be

  

level with the front surface 

of the cabinet door by using the limiter 

 screws behind the sliding part.

10

Содержание Delico PTD EC

Страница 1: ...pe A279843 1 Vallox DelicoPTD EC The Vallox Delico PTD EC control hood is suited to controlling EC roof fans and Vallox ventilation units The cooker hood is designed to be used above the cooker top as...

Страница 2: ...the light switch The light is dimmable Adjust the brightness by pressing the light switch until the brightness is adequate Ventilation modes Select the ventilation mode by pressing the ventilation mo...

Страница 3: ...lation unit turns off and the damper closes If this kind of alarm is noticed before fire damage it can be acknowledged by pressing any of the cooker hood buttons Pre selection of light brightness To m...

Страница 4: ...ooker fan must be easy to access CAUTION The cooker hood must not be connected to a flue that is used for removing combustion gases e g from a wood or gas burning fireplace cooker or stove CAUTION Reg...

Страница 5: ...RD FUNCTION NORMAL SITUATION OPEN ACTIVATED CLOSED HOUSE AUTOMATION NORMAL SITUATION OPEN ERROR SITUATION HOOD OR VENTILATION UNIT CLOSED ACTIVATED GUARD FUNCTION FLASHING POSITION OF THE DAMPER DAMPE...

Страница 6: ...mum voltage of 10 VDC Next press the ventilation mode button which sets the control voltage at 2 5 VDC After this the voltage will increase by 0 5 VDC at a time Save the selected control voltage by pr...

Страница 7: ...dp dp 2 x Boost ventilation The volume flow rate of the air inside the cooker hood is measured with the damper open based on the static pressure loss and the performance scheme of the cooker hood Meas...

Страница 8: ...Vallox DelicoPTD EC D9517 18 12 2020 www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Technical support 358 10 7732 270...