Hook-up (High voltage)
Thermo H
71
Fig. 16: Control of the electrically operated part of the heater using the pre-selection timer
5A
1
10
11
12
4
5A
5A
2
8
Spheros Thermo H
24V
600V DC
RT
BN
5
2
-
max. 10m
mind. 2,5mm²
5A
1
10
11
12
4
5A
5A
2
8
24V
SW
1
+
3/PE/N AC
400/230V 50Hz
+
Consider
prescribed protection!
- Overcurrent protection
Valeo
pre-selection
Operation indicator DC
24V DC max. 250mA
Connection
external control
Operation indicator AC
24V DC max. 250mA
T.58
T.15
T.30
T.31
timer (DC)
Valeo
pre-selection
timer (AC)
Max. 10m
at least 2.5mm²
Valeo Thermo H
Содержание Thermo H