Hook-up (High voltage)
70
Fig. 15: Control of the electrically operated part of the heater by a switch (relay)
Spheros Thermo H
600V DC
max. 10m
1
2
SW
RT
-
+
BN
5
+
-
+
+
3/PE/N AC 400/230V
50Hz
24V DC
24V DC
5A
5A
mind. 2.5mm²
Switch
at least 30V DC 1.5A
Switch
at least 30V DC 1.5A
Operation indicator DC
24V DC max. 250mA
Operation indicator AC
24V DC max. 250mA
Connection
external Control
Consider
prescribed protection!
- Overcurrent protection
Max. 10m
at least 2.5mm²