Thermo H
Hook-up (High voltage)
68
12.6. 600V DC - Overcurrent protection / insulation monitoring
device
ATTENTION:
The power supply circuit is to be protected through an all pole
overcurrent protection device according to table on page 77.
If the overcurrent device has been triggered, the heater is to be switched
off. It is essential that the cause is identified and the error rectified by a
qualified electrician in a specialised workshop. Only then the heating
appliance can be reconnected to the mains.
The use of overcurrent protection devices with another as specified load
ability is not permitted and will result in loss of the operating approval!
The heater must be protected on the vehicle side with all poles by
an insulation monitoring device (tripping resistance 0.5 M
Ω
)
against fault currents.
If the Thermo H is monitored as a subcomponent of the BUS sys-
tem, the value can be adapted according to the applicable statutory
requirements.
The hook-up of the insulation monitoring device is shown in figure 13 (for
example if monitoring the stand alone device).
The specified for the fasteners torque value must be met.
High voltage! Danger to life!
Warning!
Fig. 13:
L1
L2
L1
L2
Valeo Thermo H
Main circuit
DC 690(600) V 0Hz
IMD 0.5 M
Ω
breaker
Overcurrent
protection device
For value see table
on page 77.