1.3.5
Fresh
Air
Intake
Kit
During
operation,
the
fireplace
requires
fresh
air
for
combustion
and
draws
air
out
of
the
house.
It
may
starve
other
fuel
burning
appliances
such
as
gas
or
oil
furnaces.
As
well,
exhaust
fans
may
compete
for
air,
causing
negative
pressure
in
the
house,
resulting
in
smoke
entering
the
house
from
the
fireplace.
This
situation
is
aggravated
in
modern
airtight
houses.
To
overcome
this
problem,
we
strongly
recommend
that
you
bring
fresh
air
to
the
fireplace.
Check
with
local
authorities
having
jurisdiction
in
your
area,
it
may
be
mandatory.
THE
INSULATED
FLEXIBLE
PIPE
LENGTH
SHOULD
BE
SUFFICIENT
AND
HAVE
A
CONFIGURATION
TO
AVOID
CONDENSATION.
THE
OUTSIDE
WALL
TERMINATION
MUST
NOT
BE
INSTALLED
AT
MORE
THAN
50%
OF
THE
TOTAL
HIGHT
OF
THE
CHIMNEY
AND
AT
THE
MOST
10
FT.
(3
M)
ABOVE
THE
BASE
OF
THE
FIREPLACE.
THE
FRESH
AIR
MUST
COME
FROM
OUTSIDE
THE
HOUSE.
THE
AIR
INTAKE
MUST
NOT
DRAW
AIR
FROM
THE
ATTIC,
FROM
THE
BASEMENT,
OR
FROM
A
GARAGE.
THE
OUTSIDE
WALL
TERMINATION
SHOULD
BE
INSTALLED
WHERE
IT
IS
NOT
LIKELY
TO
BE
BLOCKED
BY
SNOW
OR
EXPOSED
TO
EXTREME
WIND
AND
AWAY
FROM
AUTOMOBILE
EXHAUST
FUMES,
GAS
METER
AND
OTHER
VENTS.
Your
fresh
air
kit
contains
the
following
components:
a.
One
(1)
4"
adapter
(D);
b.
Two
(2)
screws
(E);
The
following
components
are
not
included:
a.
A
4”
insulated
flexible
pipe
(This
HVAC
type
pipe
must
comply
to
ULC
S110
and/or
UL
181,
Class
0
or
Class
1
Standards
and
must
withstand
temperatures
up
to
250
°F.
b.
The
outside
air
inlet
cap
c.
The
2
adjustable
clamping
ring
To
complete
the
fresh
air
installation,
you
will
need
a
4"
insulated
flexible
pipe.
Use
the
length
required
for
your
installation
while
respecting
the
maximum
length
of
30
ft
(9
m).
To
avoid
condensation,
it
is
recommended
to
use
an
insulated
pipe
long
enough
and
containing
a
"P
‐
Trap"
loop.
This
configuration
can
be
found
inside
the
chase,
but
must
at
all
times
maintain
clearances
to
combustibles.
Remove
the
knock
out
(A)
located
on
the
left
‐
hand
side
of
your
fireplace.
Then
cut
and
remove
the
insulation
(B)
and
remove
the
inner
knock
‐
out
(C).
Install
4"
adapter
(D)
included
in
your
fireplace
with
the
2
screws
(E).
Содержание FP1LM Manoir
Страница 8: ...8 FP1LM Manoir Installation and Operation Manual...
Страница 9: ...FP1LM Manoir Installation and Operation Manual 9...
Страница 13: ...FP1LM Manoir Installation and Operation Manual 13...
Страница 18: ...18 FP1LM Manoir Installation and Operation Manual CLEARANCES A 16 406 mm B 46 1168 mm C 8 203 mm...
Страница 34: ...34 FP1LM Manoir Installation and Operation Manual Direct installation Exterior offset installation...
Страница 65: ...FP1LM Manoir Installation and Operation Manual 65 APPENDIX 3 EXPLODED DIAGRAM AND PARTS LIST...