24
FP1LM
Manoir
‐
Installation
and
Operation
Manual
1.3.4.3
Compliance
of
a
Combustible
Mantel
Shelf
To
ensure
compliance
of
an
existing
mantel
shelf
or
to
install
a
combustible
mantel
shelf,
refer
to
table
and
figure
in
this
section.
For
example,
a
mantel
shelf
with
a
6’’
depth
(152
mm)
((C)
value)
must
be
installed
at
least
48"
(1219
mm)
((B)
value)
above
the
bottom
of
the
fireplace
(see
figure
and
tables
in
this
section).
Different
mantel
shelf
dimensions
are
listed
in
the
following
table.
However,
no
combustible
mantel
shelf
can
be
installed
at
less
than
48"
(1219
mm)
above
the
bottom
of
the
fireplace.
If
the
depth
of
the
mantel
shelf
is
not
listed
in
the
table
below,
add
42"
(1067
mm)
to
the
depth
of
your
mantel
shelf
to
obtain
the
safe
positioning
of
your
mantel
shelf.
For
example,
for
a
9"
(229
mm)
mantel
shelf,
the
safe
positioning
would
be
51"
(1295
mm)
above
the
bottom
of
the
fireplace
42"
(1067
mm)
+
9"
(229
mm)).
CLEARANCES
A
72"
(1829
mm)
SHELF
POSITIONING
B
C
48"
(1219
mm)
6"
(152
mm)
50"
(1270
mm)
8"
(203
mm)
52"
(1321
mm)
10"
(254
mm)
54"
(1372
mm)
12"
(305
mm)
Содержание FP1LM Manoir
Страница 8: ...8 FP1LM Manoir Installation and Operation Manual...
Страница 9: ...FP1LM Manoir Installation and Operation Manual 9...
Страница 13: ...FP1LM Manoir Installation and Operation Manual 13...
Страница 18: ...18 FP1LM Manoir Installation and Operation Manual CLEARANCES A 16 406 mm B 46 1168 mm C 8 203 mm...
Страница 34: ...34 FP1LM Manoir Installation and Operation Manual Direct installation Exterior offset installation...
Страница 65: ...FP1LM Manoir Installation and Operation Manual 65 APPENDIX 3 EXPLODED DIAGRAM AND PARTS LIST...