In
the
case
where
(
F
)
would
be
equal
to
4",
it
is
suggested
that
the
sheet
metal
between
the
base
of
the
fireplace
and
floor
be
in
one
piece.
In
the
case
where
the
fireplace
is
installed
directly
on
the
floor
the
joint
between
the
hearth
extension
and
the
fireplace
(
E
)
must
also
be
protected
by
a
non
‐
combustible
material.
For
example,
a
sheet
metal
(not
included).
Note
that
the
floor
under
of
the
fireplace
should
match
or
exceed
the
height
of
the
floor
protection.