34
FP14 Cartier - Installation and Operation Manual
(optional),
outside
air
kit
and
chimney.
If
possible,
you
should
choose
a
location
where
the
chimney
will
pass
through
the
house
without
cutting
floor
or
roof
rafters.
B.
Usually,
no
additional
floor
support
is
needed
for
the
fireplace.
The
adequacy
of
the
floor
can
be
checked
by
first
estimating
the
weight
of
the
fireplace
system.
Weight
is
given
in
Section
2.1:
FP14
Cartier
Specifications
.
Next,
measure
the
area
occupied
by
the
fireplace,
note
the
floor
construction
and
consult
your
local
building
code
to
determine
if
additional
support
is
needed.
WARNING: THE FIREPLACE MUST BE INSTALLED ON A LEVEL AND STRAIGHT (NOT
UNEVEN) SURFACE.
6.3.1.1
Raised
base
installation
of
more
than
8"
(R
value
for
the
hearth
extension
not
required)
The
FP14
Cartier
may
be
installed
directly
on
the
floor
or
on
a
raised
combustible
or
non
combustible
base.
In
case
the
fireplace
is
elevated
more
than
8"
(
B
),
an
R
value
for
the
hearth
extension
is
not
required.
However,
the
upper
and
lower
angle,
for
the
full
width
of
the
floor
protection,
must
be
protected
2"
horizontally
and
vertically
(
E
)
by
a
non
‐
combustible
material.
For
example,
a
sheet
metal
(not
included).
Apart
from
these
two
corners,
the
sheet
metal
does
not
have
to
cover
the
rest
of
the
wall
between
the
base
of
the
fireplace
and
the
floor.
CLEARANCES
MINIMUM
MEASUREMENTS
A
84"
(2134
mm)
E
2"
(51
mm)
B
8"
(203
mm)
minimum
Содержание FP14 Cartier
Страница 9: ...FP14 Cartier Installation and Operation Manual 9...
Страница 10: ...10 FP14 Cartier Installation and Operation Manual...
Страница 35: ...FP14 Cartier Installation and Operation Manual 35...
Страница 55: ...FP14 Cartier Installation and Operation Manual 55 Direct installation Exterior offset installation...
Страница 91: ...FP14 Cartier Installation and Operation Manual 91 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST 61...