background image

6

947194

Figure 4.

  Connection for Single Zone Paging

100-250 V AC, 50/60 Hz

0 dBm

OU

T

CONTROLLER

UNIT

LOW 

CUT -

-

C1

RI

N

G

TI

P

70V O UT

P AGE 

DU

C

K

IN

G

P

A

G

E

 AC

C

E

S

SED

UN

B

A

L

A

N

C

E

D

 O

U

T

P

UT

OV

E

R

LOA

D

PO

W

E

R

MUSIC IN

D

R

Y

 LOOP

 H

I Z

D

R

Y

 LOOP

 600 OH

M

S

GR

OU

N

D

 S

TAR

T

L

O

O

P

 ST

AR

T

GN

D

RI

N

G

TI

P

C1

P AG

INPUT

RI

G

H

T

LE

F

T

GR

OU

N

D

IN

P

U

T

 L

E

V

E

L

+

Power Input 
24 V olts  AC

T elco In 

Loop Start

Line  In

C1   G

+  -

Output 

Level

Line Out

+  -  

C1   C

Mic Only

Mic Only

Relay Outputs

Clock Inputs or Remote Control

-24dB     -24dB    -18dB    -12dB    -6dB

NO   C 
1

NO   C 
1

NO    C  
1

NO    C  
1

NO   C 
1

NO 

1

NO 

1

NO 

1

NO 

1

C

NC

C

NC

C

NC

C

NC

CAUTION: Use only the FM-14
Log Current Microphone.
A standard microphone will be
damaged if connected to the FM-15.

damaged if connected to the FM-15.

FM-14 MICROPHONE

V-5335621

AMPLIFIER

Y R G

NOTE: 

These terminals are redundant
page input connections.  Useful
when a modular RJ-11 plug and
cable is not available. 

OR

R G B 

Y

Line Out to Page Input

S

h

ie

ld

 
Ser #

TELEPHONE 

SYSTEM

These terminals are redundant
MIC input connections.  Useful
when a modular RJ-11 plug and
cable is not available. 

PAGEPAC PLUS
CONTROLLER

Other Zones

0dBm
Output
or

Zone
CC

1/4 Modular
Cord      or

Full
Modular
Cord

Содержание Pagepac Plus V-5335621

Страница 1: ...m level in 6 dB steps The Telco input is loop start and has priority over the line input The line input has a dry contact closure which will provide an isolated dry contact closure at the connections...

Страница 2: ...or wall mount single rack space 24VAC UL listed power supply Part 15 FCC approved Dimensions Weight 17 W x 1 75 H x 8 75 D 19 W with rack ears 43 18cm x 4 45cm x 22 23cm 8 lbs 3 63 kg Environmental H...

Страница 3: ...microphone will be damaged if connected to the FM 15 FM 14 V 5335621 AMPLIFIER B Y R G OR R G B Y Line Out to Page Input 600 OHM PAGE PORT INPUT Shield NOTE These terminals are redundant page input c...

Страница 4: ...rminals are redundant page input connections Useful when a modular RJ 11 plug and cable is not available OR Set Zone to Contact Closure Output 0dbm 0dbu Line Input Line Out to Page Input V 5335621 AMP...

Страница 5: ...or Remote Control 24dB 24dB 18dB 12dB 6dB NO C 1 NO C 1 NO C 1 NO C 1 NO C 1 NO 1 NO 1 NO 1 NO 1 C NC C NC C NC C NC CAUTION Use only the FM 14 Log Current Microphone A standard microphone will be da...

Страница 6: ...18dB 12dB 6dB NO C 1 NO C 1 NO C 1 NO C 1 NO C 1 NO 1 NO 1 NO 1 NO 1 C NC C NC C NC C NC CAUTION Use only the FM 14 Log Current Microphone A standard microphone will be damaged if connected to the FM...

Страница 7: ...closures on the back panel These activate at 6 and 0 dB levels This can be used for priority override of remote level controls strobe activation or similar applications Set the manual level control t...

Страница 8: ...NO 1 NO 1 C NC C NC C NC C NC Control of External Devices Relay Outputs Clock Control or Remote Control of Levels Manual Override Mic Only Mic Only Relay Outputs Clock Inputs or Remote Control 100dB...

Страница 9: ...he FM 14 Log Current Microphone Manual Use of the Ambient Level Controller see Figure 7 The ALC may be used without the FM 14 MIC In this mode the ALC becomes a leveler or limiter for a manual control...

Страница 10: ...IN OUT 1 0 Seconds OUT IN 2 0 Seconds OUT OUT 4 0 Seconds IN IN Figure 9 Timing Adjustments for J4 and J5 Figure 10 Output Level Control Line Output Enable Output Level Control Minus 12dB Jumper J6 1...

Отзывы: