M007502200
12/07/2007
MELTON, S.L. - POLIGONO INDUSTRIAL AGUSTINOS CALLE G-34,31160 ORCOYEN, NAVARRA
TEL: 00 34 948 321580 Fax: 00 34 948 326584 e-mail:[email protected] http://www.melton.es
11
Format number:
The display will show:
* Format data *
Num: xx
Where XX is the pattern format that the system is using. This parameter
can be modified between 1 and 24.
Application type:
The display shows:
* Format data *
mould type: x
Where X can be modified between 0 and 1.
When application type is 0 the control will make a complete cycle every
time it receives an input signal.
When application type is 1 it will repeat the cycle until the input signal is
finished.
Application Mode:
The display will show:
* Format data *
Channel x mode x
Where mode can be set in either 0 or 1 for each channel.
When mode is 1 the control will enable the stitch system, making dashed
lines on the application in order to save adhesive.
Format Data:
The display will show:
* format data *
vref.: xxx m/min
Where XXX is the reference speed for the pressure control (maximum line
speed). Press
to validate the changes. The display will then show:
* format data *
Press. At vref. Xx %