Counter reset
Counter to 0 Esc
The cycles counter is activated when the application type is normal
(Application type: 0) in the menu “DATA FORMAT”; This counter counts
the made cycles through outlet channel 1 to solenoid valve. In case of
work with more than one outlet channel , we recommend to connect the
solenoid valve with the most extensive cycle device to the outlet channel
1 of the CP40.
4.3.5 Configuration menu:
When entered, the control request an access password
Configuration
Password:
If Password is ON, press at the same time
and
to enter the
menu.
Valves compensation:
* Configuration *
-- Compes. valves
Press
to enter the menu or
Esc
to exit.
The display will show:
* compens. Valves *
Activ.: xx,x ms
Where XX,X is the time in milliseconds that the guns need to close (the
time from the control signal until the adhesive stops). Press
to validate
the change. Use key
for moving among the parameters.
* compens. Valves *
Deactiv.: xx,x ms
Where XX,X is the time in milliseconds that the guns need to open. Press
to validate the change.
Standard values for these parameters are:
Simple
effect
Double
effect
Deactivatio
n
19,0 ms
9,0 ms
Activation
8,0 ms
9,0 ms