QS-2000A Requirements
To obtain 10,000 PSI output requires 60-100 PSI of air at 9 CFM.
Moisture separator and lubricator (not included) are recommended on the air supply line to
prolong the life of the pump.
If Using the Val-Tex #8607 Air Regulator
1. Install 160 psi air gauge (2052L160) in one of the LP ports on the regulator.
2. Regulator Specifications:
A. Regulator inlet capacity 3000 psi maximum
B. Output Adjustable 1-160 psi
C. Regulator preset at factory for 100 psi.
One (1) air inlet port is marked HP (High Pressure)
Two (2) air outlet ports are marked LP (Low Pressure)
Before Operating the Pump make sure all threaded connections are tight.
Loading and Operating the QS-2000A
1. Depress pump pedal to "release" position (as marked on pedal)
2. Using the handle (1413) supplied, remove sealant barrel cap (1407).
3. Use the handle (1413) to push piston assembly (2008) to the desired depth.
When less than full capacity is required, use 1 oz. marking on handle.
4. Load Val-Tex lube sealant or Valve Flush as required. Remember to remove
cellophane wrapper on sticks.
Содержание QS-2000A