SPECIFICATIONS
Model No.
PA-133, 7001
PA-166
PA-1150
Air Pressure
60 - 100 psi [4,1 - 6,9 bar]
Air Consumption
9 CFM [15 m
3
/h]
Oil Flow at 100 psi air
40 cu. in./min. at 0 psi [656 cu. cm/min at 0 bar]
8 cu. in./min. at 10,000 psi [131 cu. cm/min at 700 bar]
Usable Oil Capacity
36 cu. in.
[590 cu. cm]
72 cu. in.
[1180 cu. cm]
80 cu. in.
[1311 cu. cm]
Weight
12 lb. [5,45 kg]
16 lb. [7,27 kg]
18 lb. [8,18 kg]
dBa
85 dBa
INSTALLATION
Adding Oil to the Reservoir
1. Hold pump on end as shown in Figure 1 and remove
fill plug. On PA-1150 models, the fill plug is located
on the side of the pump as shown in Figure 2.
2. Fill to
1
/
2
" [1 cm] below the fill opening with Enerpac hydraulic oil. Use of fluids
other than Enerpac hydraulic oil may cause damage and will void your warranty.
WARNING
Attempting to overfill the reservoir will cause the reservoir to become pressurized.
If the reservoir is subjected to high pressure, the casing may rupture, causing
personal injury and/or equipment damage.
3. Replace the fill plug and finger tighten.
CAUTION
DO NOT use a wrench. Over-tightening will tear the reservoir bladder.
4. Tip the pump and check for leakage. If leakage occurs, remove the plug and check
the plug seal for cuts or nicks. Replace the seal if necessary.
5. Replace the fill plug making sure the seal is centered properly on the plug. If leakage
still occurs, remove oil and take pump to your nearest Enerpac Service Center.
®
Figure 1
Figure 2
2
Содержание QS-2000A
Страница 1: ......