5. Replace sealant barrel (1407) cap. Tighten with handle (1413) provided.
WARNING: FAILURE TO COMPLY WITH THE FOLLOWING SAFETY PROCEDURE
COULD RESULT IN SERIOUS INJURY: THE SEALANT CAP MUST BE COMPLETELY
SCREWED ONTO THE BARREL BEFORE OPERATING THIS UNIT. THE YELLOW
SAFETY GAUGE MUST BE LIFTED UP AND THE BOTTOM SIDE OF THE TAB MUST
CLEAR THE TOP OF THE CAP.
6. Activate pump by pressing the pedal to "pump" (as marked on pedal). Continue
until material flows from end of hose. * Pedal requires constant pressure to
maintain operation.
7. Before removing the coupler from the valve or when the hydraulic pump is not in
use, release the pressure on the hydraulic pump.
8. When the cylinder is empty the pump will begin to stall. Stop the pump. Please
refer to step #1.
WARNING! If the pump is activated when the sealant barrel cap (1407) is
removed, the piston assembly (2008) can be pumped out of the cylinder.
* Dispose of any expelled material properly.
SAFE
STOP