Data Number
Description
1
Ray history array consisting of six words per ray for the last 40 rays (in reverse time
order) that were processed. Each six- word group holds:
• Number of samples that went into the ray
• Time since the last ray (in tenths of ms)
• Ending azimuth TAG bits
• Ending elevation TAG bits
• Starting azimuth TAG bits
• Starting elevation TAG bits
2
Angle sync table from last
LDSYNC
command.
3
Reserved (was
AGC
table)
4
Filter selection array from the last
LFILT
command. This returns the filter selection
codes, one per word, for all range bins described by filter slot #0.
5
Reserved (was
STC
table)
6
Custom range normalization from last
LDRNV
command.
7
Samples of the TAG input lines at 4 ms intervals. The sampling begins at the moment
the
RBACK
command is received, and continues until the output count is reached. Each
32-bit sample is output as a pair of 16-bit words:
• Azimuth (TAG bits 0–15)
• Elevation (TAG bits 16–31)
8
Doppler clutter filter coefficients (Same format as for
LFCOEFS
command)
9
Reserved (was
LOG
clutter filter coefficients)
10
Range mask spacing in cm for each pulse width
11
Current value of UIQ bits from
Set/Clr
all prior operations
12
Individual threshold configuration for each data type.
This allows read back of the threshold table set with the
THRESH
command. See
Set Individual Thresholds (THRESH) (page 315)
Outputs 7 words per data type.
Datatypes in the order specified in the selection mask.
13
Extended parameter information defined in
struct dspExParmIO
.
14
Minimum and maximum values of the optional I/O-62 A/D converter, sampled over at
least one complete pulse period. 16-bit signed outputs represent the full range of the
A/D converter. When the RVP98D backpanel is connected, the first Min/Max pair
samples the
LOGVideo
input, the second pair samples the
CathodePulse
input, and
the third and fourth pairs sample internal levels.
15
Returns an array of
struct RVP9SpecFiltIO
structures for each of the non-zero
clutter filter definitions, beginning with #1. This is the same format used by the
LFSPECS
command to define each clutter filter. The order is as defined in the
PPRMS_N_* #defines
in
rvp9.h
.
16
Returns the identifiers of the currently active HydroClass classifier algorithms. The
identifiers are encoded in
sig_data_types.h
.
Chapter 8 – Host Computer Commands
305
Содержание RVP900
Страница 1: ...M211322EN J User Guide RVP900 Digital Receiver and Signal Processor RVP900...
Страница 19: ...RVP9IFD China RoHS Compliance RVP901 AC and RCP903 China RoHS Compliance Chapter 2 Product Overview 17...
Страница 22: ...RVP900 User Guide M211322EN J 20...
Страница 88: ...RVP900 User Guide M211322EN J 86...
Страница 170: ...RVP900 User Guide M211322EN J 168...
Страница 236: ...RVP900 User Guide M211322EN J 234...
Страница 390: ...RVP900 User Guide M211322EN J 388...
Страница 434: ...Figure 68 ASR9 WSP with RVP7 Architecture RVP900 User Guide M211322EN J 432...
Страница 456: ...Figure 82 J90 to J111 Wiring Diagrams RVP900 User Guide M211322EN J 454...
Страница 457: ...Figure 83 J13 Wiring Diagram Appendix H TDWR Customizations 455...
Страница 468: ...RVP900 User Guide M211322EN J 466...
Страница 482: ...RVP900 User Guide M211322EN J 480...
Страница 483: ......
Страница 484: ...www vaisala com...